Chapter 2
Message and Recovery Procedures
Error Message CFGMGR-1-UNABLE_TO_SEND_STARTUP_CFG: unable to send startup-cfg, bits:
[hex], retrying...
Explanation
startup configuration file to the stack member switches. [hex] is the bit representation of the switch
number.
Recommended Action
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting Cisco, see the
Traceback Reports" section on page
Error Message CFGMGR-3-ERROR_APPLYING_STARTUP_CFG: Error Applying Startup Config to
Running Config.
Explanation
applying the startup configuration to the running configuration.
Recommended Action
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
Message Traceback Reports" section on page
Error Message CFGMGR-4-SLAVE_WRITING_STARTUP_CFG: only master can do that.
Explanation
configuration file; only the stack master can write to the startup configuration file.
Recommended Action
Error Message CFGMGR-5-UNABLE_TO_USE_PROVISIONED_CFG: Switch [dec] will receive the
default configuration.
Explanation
provisioned configuration for its switch number; therefore, the default configuration is applied to
this switch. [dec] is the stack member number.
Recommended Action
Error Message CFGMGR-6-APPLYING_RUNNING_CFG: as new master.
Explanation
configuration.
Recommended Action
78-16184-04
This message means that the system is unsuccessfully attempting to distribute the
Find out more about the error by using the show tech-support privileged EXEC
1-5.
This message means that the system encountered an error when it was automatically
Copy the message exactly as it appears on the console or in the system log.
This message means that a stack member switch (slave) attempted to write to the startup
No action is required.
This message means that the switch type of the specified switch does not match the
No action is required.
This message means that a new stack master is applying the backed-up running
No action is required.
1-5.
Catalyst 3750 Switch System Message Guide
CFGMGR Messages
"Error Message
"Error
2-9