8.5 Setting up the energy metering
8.5.1 Consumed energy
8.6 Setting up the power consumption control
EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P531180-1D – 2025.03
Configuration
The outdoor unit can control DHW pump operation. For more information, see
4
"11 Configuration" [
136].
▪
Via the user interface, you can read out the following energy data:
-
Consumed energy (electricity)
-
Consumed gas (only in case of EHY2KOMB28+32AA gas boiler)
▪
You can read out the energy data:
-
For space heating
-
For domestic hot water production
▪
You can read out the energy data:
-
Per two hours (for the last 48 hours)
-
Per day (for the last 14 days)
-
Per month (for the last 24 months)
-
Total since installation
INFORMATION
The calculated consumed energy (electricity) and consumed gas are estimations, the
accuracy cannot be guaranteed.
You can use the following methods to determine the consumed energy:
▪
Calculating
Calculating the consumed energy
▪
The consumed energy is calculated internally based on:
-
The actual power input of the outdoor unit
-
The set capacity of the bottom plate heater (if applicable)
-
The voltage
▪
Setup and configuration: To get accurate energy data, measure the capacity
(resistance measurement) and set the capacity via the user interface for the
bottom plate heater (if applicable).
▪
The power consumption control:
-
Allows you to limit the power consumption of the outdoor unit.
-
Configuration: Set the power limitation level and how it has to be achieved via
the user interface.
▪
The power limitation level can be expressed as:
-
Maximum running current (in A)
-
Maximum power input (in kW)
▪
The power limitation level can be activated permanently, but not by digital
inputs.
8
Application guidelines
|
Installer reference guide
61