Installer settings: Tables to be filled in by installer ....20 Indicates a situation that could result in explosion. 4.10.1 Quick wizard ............... 20 4.10.2 Space heating control ..........20 User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
▪ Format: Paper (in the box of the outdoor unit) ▪ Installation and operation manual – Gas boiler module: ▪ Installation and operation instructions ▪ Format: Paper (in the box of the gas boiler) EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
▪ Format: Paper (in the box of the outdoor unit) + Digital files on http://www.daikineurope.com/support-and-manuals/product- information/ Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. The original documentation is written in English. All other languages are translations. Available screens Depending on your system layout and installer configuration, not all screens in this document may be available on your user interface.
Domestic hot water operation. Actual temperature. Desired temperature. At the next scheduled action, the desired temperature will increase. At the next scheduled action, the desired temperature will NOT change. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
To turn ON or OFF the main leaving water temperature control 2 Press again to display the next home page (if any). 1 Go to the main leaving water temperature home page (LWT main) 2 Press User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
You can set the leaving water set point on ▪ "4.4.6 Room thermostat control - Using the leaving water the home page. temperature home pages" on page 9 ▪ "4.7 Preset values and schedules" on page 16 EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
AND changing the mode to preset value The next scheduled action is at You have configured the following settings: 17:00 and the desired temperature will then increase. User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
(main) by adjusting scheduled 20°C, but to the preset value (Eco = 18°C). After 2 hours, preset values. the room will heat up again to the scheduled 20°C. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
External room thermostat control means that you control the following: ▪ Room temperature on the external thermostat control ▪ Leaving water temperature on the user interface (Daikin) To control the leaving water temperature, you can do the following: ▪ T : Room temperature ▪...
DHW tank temperature home page (example: 15°C). (example: 50°C). ▪ At 00:00 the DHW tank is programmed to heat up the water to a preset value (example: Storage comfort = 60°C). EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
Page 12
(Eco; example: 55°C and sufficient for 2 persons) at 14:00 Do the same things as in scheduled mode. — ▪ This evening you need hot water for 3 persons User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
To set the user permission level to Advanced end user If you are in the following situation: 1 Go to the main menu or any of its submenus: 2 Press for more than 4 seconds. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
1 Go to [2.1]: > Holiday > Holiday. 2 Do one of the following: ▪ To activate, select Yes and press ▪ To deactivate, select No and press User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
ON/OFF. Actual temperature 20.0°C [6.6] Operation modes Current operation mode. Scheduled 17:30 Actual temperature Example: Defrost/oil return mode. [6.7] Running hours Running hours of the system. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
Control Possible actions Room temperature Program when to heat up a space: Main leaving water ▪ Comfort (preset value) temperature ▪ Eco (preset value) ▪ [Custom temperature] User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
1 Go to [7.7]: > User settings > Set weather dependent. 2 For main leaving water temperature zone [7.7.1], modify with , and confirm with Set weather-dependent heating User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
[7.7.1] Main Set weather-dependent heating Only applicable in case of EHY2KOMB28+32AA gas boiler INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
1 Go to [7.3.8]: > User settings > Set schedules > Elec price. 2 Program the schedule according to the High, Medium and Low electricity prices for each time interval. User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
▪ If heating up the DHW tank once at night is not sufficient, program to additionally heat up the DHW tank to a preset value (Storage eco = lower DHW tank temperature) during the day. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
Increase the desired leaving cannot be reached. water temperature in accordance ▪ Be aware that the refrigerant inside the system is with the heat emitter type. odourless. User reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
MUST comply with applicable legislation. Units MUST be treated at a specialised treatment facility for reuse, recycling and recovery. EJHA04AAV3 + EHY2KOMB28+32AA User reference guide Daikin Altherma hybrid monobloc 4P531181-1 – 2018.06...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with product according instructions accompanying documentation.