11
|
Configuration
Installer reference guide
146
Leaving water temperature: Main zone
#
[A.3.1.1.1]
N/A
[A.3.1.1.1]
N/A
[7.7.1.1]
[1‑00]
[1‑01]
[1‑02]
[1‑03]
Code
LWT setpoint mode:
0
Fixed:
temperature is:
-
NOT weather-dependent (i.e. does NOT
depend
temperature)
-
fixed in time (i.e., NOT scheduled)
1 Weather dep.: The desired leaving water
temperature is:
-
weather-dependent (i.e. depends on the
outdoor ambient temperature)
-
fixed in time (i.e., NOT scheduled)
<< continuation
2 Fixed/scheduled: The desired leaving
water temperature is:
-
NOT weather-dependent (i.e., does NOT
depend
temperature)
-
according a schedule. The scheduled
actions consists of desired shift actions,
either preset or custom.
Remark: This value can only be set in
leaving water temperature control.
3 WD/scheduled: The desired leaving water
temperature is:
-
weather-dependent (i.e., does depend on
the outdoor ambient temperature)
-
according a schedule. The scheduled
actions consists of desired leaving water
temperatures either preset or custom
Remark: This value can only be set in
leaving water temperature control.
Set weather-dependent heating:
T t
[1-02]
[1-03]
[1-00]
T
: Target leaving water temperature (main)
t
T
: Outdoor temperature
a
Description
The
desired
leaving
on
the
outdoor
continued >>
on
the
outdoor
[1-01]
T a
continued >>
EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma H Hybrid
4P531180-1D – 2025.03
water
ambient
ambient

Advertisement