DHW pump for instant hot water........................8.4.5 DHW pump for disinfection........................... Setting up the energy metering ............................. 8.5.1 Consumed energy ............................Setting up the power consumption control ........................Installer reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 3
10.9.9 Fitting a vertical flue system.......................... 125 10.9.10 Plume management kit..........................125 10.9.11 Flues in voids..............................126 10.9.12 Flue gas materials (C63) available on the market..................127 EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 4
16.4.10 Symptom: Boiler/hydrobox combination abnormality (UA-52 error) ............209 16.4.11 Symptom: The burner does NOT ignite......................210 16.4.12 Symptom: The burner ignites noisily......................210 16.4.13 Symptom: The burner resonates........................210 Installer reference guide EJHA04AAV3 + EHY2KOMB28+32AA Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 5
Gas boiler..................................230 18.2.1 Components: Gas boiler ..........................230 18.2.2 Wiring diagram: Gas boiler ..........................231 18.2.3 Technical specifications: Gas boiler....................... 232 19 Glossary 20 Field settings table EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Heating and Hotwater Industry Council who manage and promote the Scheme. Visit http://www.centralheating.co.uk for more information. a Gas boiler module INFORMATION This product is intended for domestic use only. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Format: Paper (in the box of the outdoor unit) ▪ User reference guide: Detailed step-by-step instructions and background information for basic and advanced usage Format: Digital files on https://www.daikin.eu. Use the search function find your model. ▪ Installation manual – Heat pump module: Installation instructions Format: Paper (in the box of the outdoor unit) ▪...
A subset of the latest technical data is available on the regional Daikin website (publicly accessible). ▪ The full set of the latest technical data is available on the Daikin Business Portal (authentication required). 2.2 Installer reference guide at a glance...
Page 9
Note: There is also an installer settings table in the user reference guide. This table has to be filled in by the installer and handed over to the user. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
WARNING: FLAMMABLE MATERIAL CAUTION Indicates a situation that could result in minor or moderate injury. NOTICE Indicates a situation that could result in equipment or property damage. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
WARNING Improper installation or attachment of equipment or accessories could result in electrical shock, short-circuit, leaks, fire or other damage to the equipment. ONLY use accessories, optional equipment and spare parts made or approved by Daikin unless otherwise specified. WARNING Make sure installation, testing and applied materials comply with applicable legislation (on top of the instructions described in the Daikin documentation).
If the wall on which the unit is mounted is flammable, a non-flammable material must be placed between the wall and the unit. Do the same for all locations through which the flue piping passes. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Toxic gas might be produced if refrigerant gas comes into contact with fire. WARNING ALWAYS recover the refrigerant. Do NOT release them directly into the environment. Use a vacuum pump to evacuate the installation. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 14
Charge with the cylinder upside down. ▪ Open refrigerant cylinders slowly. ▪ Charge the refrigerant in liquid form. Adding it in gas form may prevent normal operation. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Using filling water and top-up water which does NOT meet the stated quality requirements can cause a considerably reduced service life of the equipment. The responsibility for this is entirely that of the user. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
MUST be as such that the current-carrying wires are tautened before the earth wire is in case the power supply is pulled loose from the stress relief. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The meter or regulator and pipe work to the meter MUST be checked preferably by the gas supplier. This is to ensure that the equipment works good and meets the gas flow and pressure requirements. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
BS 5549: 1990 Forced circulation hot water systems. ▪ BS 6700: 2006 + A1: 2009 Design, installation, testing and maintenance of services supplying water for domestic use within buildings and their curtilages - Specification EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 19
Potable water: all seals, joints and compounds (including flux and solder) and components used as part of the secondary domestic water system MUST be approved by WRAS. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed ONLY by authorised persons. EJHA04AAV3 + EHY2KOMB28+32AA...
Page 21
▪ In order to place the condensate trap, the front cover MUST be pulled forward or removed entirely. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 22
Heart, kidney or liver damage in case of glycol swallowing or skin contact with glycol. ▪ Nausea, sickness and diarrhea in case of glycol inhalation. WARNING Ethylene glycol is toxic. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 23
For installation in damp rooms, a fixed connection is obligatory. When working on the electrical circuit ALWAYS isolate the electric supply. CAUTION Do NOT push or place redundant cable length into the unit. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 24
Make sure that the flue system has a uniform gradient back to the boiler. WARNING Flue materials of different markings must NOT be combined. The boiler must NOT be installed to a pressurized common flue system (more than one boiler). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 25
ALWAYS comply with local and national regulations. The gas valve is sealed. In Belgium, any modifications to the gas valve MUST be performed by a certified representative of the manufacturer. For more information, contact your dealer. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 26
If necessary, place a new seal and check the correct positioning. ▪ If retarders are NOT or incorrectly fitted, it may lead to serious damage. Troubleshooting (see "16 Troubleshooting" [ 205]) DANGER: RISK OF ELECTROCUTION EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 27
▪ Use a separate recovery system so that the unit's compressor does NOT have to operate. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
To avoid injury, do NOT touch the air inlet or aluminium fins of the unit. NOTICE To prevent damage to the supporting feet, do NOT tilt the unit sideways in any way: Carry the unit slowly as shown: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Cable gland j Drain plug 5.3 Gas boiler 5.3.1 To unpack the gas boiler Before unpacking, move the gas boiler as close as possible to its installation position. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 30
About the box WARNING Tear apart and throw away plastic packaging bags so that nobody, especially children, can play with them. Possible consequence: suffocation. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
5.3.2 To remove the accessories from the gas boiler 1 Remove the accessories. a Mounting strip b Condensate trap c Installation and operation manual d Current loop module, cable and installation manual EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Using this gas boiler, you can produce domestic hot water as follows: ▪ Domestic hot water by tank ▪ Instant domestic hot water by gas boiler EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Using this gas boiler, you can only produce domestic hot water as instant domestic hot water by gas boiler. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 34
To prevent freeze-up of the water piping, the third-party gas boiler must have a fixed setpoint ≥55°C, or a weather-dependent setpoint ≥T (°C) –30 –25 –20 –15 –10 –5 (°C) Outdoor temperature Minimum weather-dependent setpoint for third-party gas boiler EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
If you install the bottom plate heater, you may lower the operation range of the heat pump to Ta≥–14°C using field setting [8-0E]=–14°C. ▪ If you do not install the bottom plate heater, keep [8-0E]=–5°C. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Example: EJ H A 04 AA V3 Code Explanation Hybrid monobloc outdoor pair heating only Low water temperature – ambient zone 3 (see operation range) Refrigerant R32 Capacity class Model series Power supply EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Gas group and gas connection pressure as set at the factory (EN 437) G25-25 mbar C13(x), …., C93(x) Approved flue gas category (EN 15502) Tmax Maximum flow temperature in °C IPX4D Electrical protection class EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
LAN adapter for smartphone control + Smart Grid applications (BRP069A61) You can install this LAN adapter to: ▪ Control the system via a smartphone app. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 39
Only applicable in case of EHY2KOMB28+32AA gas boiler. For providing domestic hot water, a domestic hot water tank can be connected to the gas boiler. The following domestic hot water tanks are available: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 40
The PC cable makes a connection between the switch box of the outdoor unit and a PC. It gives the possibility to update the software of the outdoor unit. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
To fill and top up the space heating system. EKFL1A Solar water heater connection set To combine the boiler with a solar heated tank. EKSH1A Dongle set EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 46
For the installation of the flue and air supply duct material, see the manual included with the materials. Contact the manufacturer of the relevant flue and air supply duct materials for extensive technical information and specific assembly instructions. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
▪ Which heat emitter types are used in each room and what is their design leaving water temperature? Once the space heating requirements are clear, Daikin recommends to follow the setup guidelines below. INFORMATION In case an external room thermostat is used and room frost protection needs to be guaranteed in all conditions, then you have to set auto emergency [A.6.C] to 1.
For your daily needs, you can use preset values and schedules. To deviate from your daily needs, you can temporarily overrule the preset values and schedules, or use the holiday mode. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 49
OFF condition. ▪ Code: [C-05] Benefits ▪ Wireless. The Daikin external room thermostat is available in a wireless version. ▪ Efficiency. Although the external room thermostat only sends ON/OFF signals, it is specifically designed for the heat pump system. Heat pump convectors...
Page 50
▪ The heat pump convectors are directly connected to the gas boiler. ▪ The desired room temperature is set via the remote controller of the heat pump convectors. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The underfloor heating of the main room is directly connected to the gas boiler. ▪ The room temperature of the main room is controlled by the user interface used as thermostat. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 52
Configuration Setting Value Unit temperature control: 0 (LWT control): Unit operation is decided based on the leaving water ▪ #: [A.2.1.7] temperature. ▪ Code: [C-07] EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 53
Compared with heat pump convectors for one room: ▪ Comfort. You can set the desired room temperature, including schedules, for each room via the remote controller of the heat pump convectors. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
How many rooms are heated by the heat pump system? ▪ Which heat emitter types are used in each room and what is their design leaving water temperature? EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Application guidelines Once the space heating requirements are clear, Daikin recommends to follow the setup guidelines below. INFORMATION In case an external room thermostat is used and room frost protection needs to be guaranteed in all conditions, then you have to set auto emergency [A.6.C] to 1.
▪ #: [A.2.1.7] temperature of the user interface. ▪ Code: [C-07] Benefits ▪ Cost effective. You do NOT need an additional external room thermostat. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Only applicable in case of EHY2KOMB28+32AA gas boiler. 8.4.1 System layout – Standalone DHW tank See "Dedicated gas boiler + Domestic hot water via tank" in "6.1.1 Dedicated gas boiler" [ 32]. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
▪ =15°C Then V =307 l DHW consumption (equivalent hot water volume at 40°C) Required DHW tank volume if only heated once DHW tank temperature Cold water temperature EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Connecting the water piping of the standalone DHW tank to the gas boiler, see the installation manual of the DHW tank, the addendum book for optional equipment, and "To connect the electrical wiring to the gas boiler" [ 108]. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
If applicable legislation requires disinfection of the water piping until the tapping point, you can connect a DHW pump and heater element (if needed) as shown above. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The power limitation level can be expressed as: Maximum running current (in A) Maximum power input (in kW) ▪ The power limitation level can be activated permanently, but not by digital inputs. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
When the power saving functionality of the outdoor unit is active (see "11 Configuration" [ 136]), the outdoor unit is turned down to reduce standby energy losses. As a result, the outdoor ambient temperature is NOT read out. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 63
The external outdoor ambient sensor data (either averaged or instantaneous) is used in the weather-dependent control curves. To protect the outdoor unit, the internal sensor of the outdoor unit is always used. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
>250 >250 >250 (mm) a Air outlet b Air inlet NOTICE The height of the wall on the outlet side of the outdoor unit MUST be ≤1200 mm. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 65
This is to prevent corrosion caused by high levels of salt in the air, which might shorten the life of the unit. Install the outdoor unit away from direct sea winds. Example: Behind the building. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 66
The appliance shall be stored so as to prevent mechanical damage and in a well- ventilated room without continuously operating ignition sources (example: open flames, an operating gas appliance or an operating electric heater). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
WARNING Make sure installation, servicing, maintenance and repair comply with instructions from Daikin and with applicable legislation (for example national gas regulation) and are executed ONLY by authorised persons. 9.2.2 Additional installation site requirements of the outdoor unit in cold climates Protect the outdoor unit against direct snowfall and take care that the outdoor unit is NEVER snowed up.
Page 68
Solutions Navigator which reached https:// professional.standbyme.daikin.eu. Please contact your dealer if you have no access to Heating Solutions Navigator. This recommendation ensures good operation of the unit, however, local regulations may differ and shall be followed. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D –...
Page 69
Start-up with glycol at – 44 m 30 m 15°C → 7.0 l/min ΔT 5°C with glycol at 20°C 36 m 14 m → 12.8 l/min ΔT 8°C with glycol at 20°C 170 m 120 m → 8.0 l/min EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Water flow. See "9.3.4 To check the water volume and flow rate" [ 73]. Minimum required flow rate 7 l/min (a) Below this value, no stable operation can be guaranteed. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 71
Domestic hot water tank – Capacity. To avoid stagnation of water, it is important that the storage capacity of the domestic hot water tank meets the daily consumption of domestic hot water. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The pre-pressure (Pg) of the vessel depends on the installation height difference (H). For more information on the formula, see the manual of the third-party expansion vessel. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Changing the pre-pressure of the expansion vessel should be done by releasing or increasing nitrogen pressure through the Schrader valve of the expansion vessel. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Normal power supply b Hydro part of the outdoor unit c Refrigerant part of the outdoor unit d Gas boiler 1 Power supply for outdoor unit EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
(c) Part of optional equipment (d) Minimum cable section 0.75 mm². (e) Cable section 0.75 mm² till 1.25 mm²; maximum length: 200 m. These wires MUST be sheathed. Recommended strip length: 6 mm. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 76
The following figure is an example and may NOT completely match your system layout. a Outdoor unit b Third-party gas boiler c Power supply for gas boiler Connections to outdoor unit: Item Description Wires Maximum running current Power supply EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 77
Recommended strip length: 6 mm. (g) Field supplied NOTICE More technical specifications of the different connections are indicated on the inside of the outdoor unit. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
DANGER: RISK OF ELECTROCUTION Do NOT leave the unit unattended when the service cover is removed. 10.2.2 To open the outdoor unit DANGER: RISK OF ELECTROCUTION DANGER: RISK OF BURNING/SCALDING EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
1 Open the gas boiler, see "10.2.3 To open the gas boiler" [ 79]. 2 Pull the boiler controller unit forwards. The boiler controller will tip downwards to provide access. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Additionally, make sure the unit is positioned at least 100 mm above the maximum expected level of snow. INFORMATION The maximum height of the upper protruding part of the bolts is 15 mm. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 81
Installation Anchor points 4× M8/M10 (mm) Option 1: On mounting feet "flexi-foot with strut" (mm) a Maximum snowfall height Option 2: On plastic mounting feet EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Option 3: On a pedestal (mm) Option 4: On brackets to the wall 4× (mm) a Anti-vibration rubber (field supply) 10.3.4 To install the outdoor unit 4× M8/M10 EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
3 Insert a rubber sheet between the cables and the outdoor unit to prevent the cables from scratching the paint (field supply). 4 Attach the ends of the cables. 5 Tighten the cables. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
4 Tilt the top of the unit at the position of the wall bracket and slide the boiler downwards to fix the boiler bracket onto the wall bracket. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
4 Connect the flexible tube (where applicable with the overflow pipe from the pressure relief valve) to the drain via an open connection. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
A suitable permanent connection to the foul waste pipe should be used. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 87
A suitable permanent connection to the foul waste pipe should be used. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Protecting the water circuit against freezing. Filling the space heating circuit. Filling the domestic water circuit of the gas boiler. Filling the domestic hot water tank (if applicable). Insulating the water piping. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
...) instantly if this can result in an immediate short circuit of the water flow between the outlet and the inlet of the unit (for example via a bypass valve). This may trigger an error. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 90
If this is NOT working correctly, overpressure will deform the tank and water leakage may occur. To confirm good operation, regular maintenance is required. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
10.6.4 Connecting the water piping of the gas boiler To connect the water piping for domestic hot water (not applicable for Switzerland) 1 Flush the installation thoroughly to clean. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 92
1 Rinse the space heating installation carefully. 2 Connect the space heating outlet (a) and space heating inlet (b) to their connections as indicated in the following illustration: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Heart, kidney or liver damage in case of glycol swallowing or skin contact with glycol. ▪ Nausea, sickness and diarrhea in case of glycol inhalation. Freeze protection by glycol EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 94
You can use either propylene glycol domestic hot water tank ethylene glycol Propylene glycol, including the necessary inhibitors, classified as Category III according to EN1717. WARNING Ethylene glycol is toxic. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 95
Vacuum breaker (head-up for air supply) These parts are necessary to protect the piping inside the outdoor unit against freezing. Note: These parts do NOT protect the field piping against freezing. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 96
Vacuum breaker (head-up for air supply) 1 Open the top plate. 2 Open the front plate. 3 Open the rear plate. 4 Connect a+b1 as follows: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 97
Head-up for air supply. Possibility 1 With option EKBALLV1 (shut-off valves with integrated connection for the vacuum breaker). For installation instructions, see the installation manual of the shut-off valves. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
10 Check the pressure again. If it is too low, repeat from step 5. 11 Disconnect the water supply hose from the fill/drain point. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 99
11 Check the pressure again. If it is too low, repeat from step 5. 12 Disconnect the water supply hose from the fill/drain point. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Connecting the LAN adapter (if applicable)(see the installation manual of the LAN adapter and addendum book for optional equipment). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
MUST NOT be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly turned ON and OFF by the utility. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
2 Install a round crimp-style terminal on the end of the wire. Place the round crimp-style terminal on the wire up to the covered part and fasten the terminal with the appropriate tool. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
78]. 2 Strip insulation (20 mm) from the wires. a Strip wire end to this point b An excessive strip length may cause electrical shock or leakage EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 104
Connections in case of dedicated gas boiler Routing Possible cables (depends on the installed options) Main power supply Main power supply (high voltage) User interface (mandatory option) User interface (low voltage) EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 105
1N~ 50 Hz 220-240 V 1× a Recommended field fuse: 20 A Q1DI Earth leakage circuit breaker 2 Fix the cable with cable ties to the cable tie mountings. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 106
Reinstall the faceplate onto the wallplate. Be careful NOT to pinch the wiring when attaching the frontplate to the unit. 4A From the rear 4B From the left 1× 1× EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 107
2 Fix the cable with cable ties to the cable tie mountings. To connect the domestic hot water pump 1 Connect the domestic hot water pump cable to the appropriate terminals as shown in the illustration below. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 108
To connect the electrical wiring to the gas boiler 1 Open the gas boiler. 2 Open the switch box cover of the gas boiler. 3 Enter the wiring through the bottom of the unit. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
10.7.5 In case of third-party gas boiler To connect the electrical wiring to the outdoor unit NOTICE The distance between the high voltage and low voltage cables should be at least 50 mm. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 110
5 Inside the unit, route the wiring to the switch box as follows: 3× a~d See below 6 Inside the switch box, connect the wires to the appropriate terminals. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 111
1N~ 50 Hz 220-240 V 1× a Recommended field fuse: 20 A Q1DI Earth leakage circuit breaker 2 Fix the cable with cable ties to the cable tie mountings. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 112
Reinstall the faceplate onto the wallplate. Be careful NOT to pinch the wiring when attaching the frontplate to the unit. 4A From the rear 4B From the left 1× 1× EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 113
EKADDONJH and EKADDONJH2 (= connection kit for third-party gas boiler). This includes connecting the external pump to the outdoor unit. For installation instructions, see the installation manual of the connection kit. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Carefully follow the instructions as described in the adapter set. The concentric adapter piece is equipped with a measuring point for the gas exhaust and one for the air intake. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
2× Ø80 by an adapter set. 1 Remove the concentric pipe from the air supply and combustion gas pipe at the top of the gas boiler by turning counterclockwise. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The total permitted pipe length of the air supply and the combustion gas flue is indicated for each appliance category. Equivalent length for concentric installation (60/100) Length (m) Bend 90° Bend 45° EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 117
For a dual pipe connection, all defined lengths assume a diameter of 80 mm. Sample calculation for dual pipe application Pipe Pipe length Total pipe length Flue pipe L1+L2+L3+(2×2) m 13 m Air supply L4+L5+L6+(2×2) m 12 m EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Combustion air is drawn into the appliance from the room by means of a concentric duct, which encloses the flue. The air enters through defined orifices situated in the surface of the duct. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 119
Best recommended position of the bracket is just before the joint. INFORMATION Flexible flue gas lines may NOT be used in horizontal connection sections. 60/100 60/100 Twin-80 Twin-80 L1 (m) L1 (m) L1 (m) L1 (m) EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 120
L2. For example: if the length of L1 is 2 m, L2 can maximally be 8 m long. L2=–1.8×L1+11.8 Multi-boiler installation INFORMATION All piping lengths in the tables below are maximum equivalent piping lengths. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 121
: See the table below for the minimum diameters of the combined gas exhaust/air intake system. For EHY2KOMB28AA: Number of Concentric Dual pipe units Gas exhaust Air intake Gas exhaust Air intake EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 122
Dual pipe units Gas exhaust Air intake Gas exhaust Air intake Special remark regarding C : The minimum inner dimensions of the chimney have to be 200×200 mm. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Especially for UK: Only use flue products approved by the boiler manufacturer, which can be bought from the supplier of your boiler. "7.3 Combining units and options" [ 38]. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 124
If this occurs, it is highly possible the flue is fitted with a negative pressure area and therefore a plume management kit MUST be fitted. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
(excluding the initial boiler connection). CAUTION Read the installation manuals of the field supplied parts. 10.9.10 Plume management kit See the local and national regulations. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The term void includes ceiling voids, floor voids, purpose built enclosures, service risers, roof spaces or any other enclosure that will restrict access to inspect the flue. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Do NOT mix flue parts or clamps of different suppliers. 10.9.14 Placing brackets on the flue gas piping The piping MUST be pushed downwards by positioning the bracket correctly. a Bracket EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 129
Position the first clamp at a maximum of 500 mm from the gasboiler. Make sure that the material of the bracket matches the material of the piping (air/ flue gas): EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 130
If extension tubes before and after the first bend are shorter than 0.25 m, the second element of the sleeve after the first bend must be fitted with a fixing bracket. element after the 1 bend EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 131
Place a fixing bracket between the fixing brackets in case of the metal piping. In case of vertical flue gas piping If the distance between the fixing brackets on sleeves is greater than 2 meters: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 132
Position a securing bracket on the last element before the wall. ▪ When this last element is an elbow, the bracket may also be placed on the previous bracket. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
10.11 Finishing the gas boiler installation 10.11.1 To perform an air purge on the gas supply 1 Turn once the screw counterclockwise. Result: Gas supply will purge air. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
2 Tilt the bottom side of the front panel towards the gas boiler. 3 Screw both screws of the cover. 4 Close the display cover. 10.11.3 To install the gas boiler cover plate EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 135
Installation The boiler cover plate is an optional product. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Accessing settings via the code in the overview Code settings. For example: [C-07] See also: ▪ "To access the installer settings" [ 137] ▪ "11.1.5 Menu structure: Overview installer settings" [ 170] EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 137
An additional 0-digit is added to the first part of the setting when you access the codes in the overview settings. Example: [1‑01]: "1" will result in "01". EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 138
1 At power ON and as long as the system layout was not confirmed yet, select your preferred language. Language Select the desired language Confirm Adjust EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Quick wizard: Standard Space heating settings The system can heat up a space. Depending on the type of application, the space heating settings must be made accordingly. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Remark: continuous pump operation requires more energy than sample or request pump operation. a: Space heating control (user interface) b: OFF c: ON d: Pump operation continued >> EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 141
Glycol present: ▪ 0 (No): No glycol was added to the water circuit. ▪ 1 (Yes): Glycol was added to the water circuit to protect it against freezing. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Domestic hot water tank: ▪ 0 (Type 1): EKHWS*D* or third-party tank (see below). ▪ 4 (Type 5). EKHWP. ▪ 6 (Type 7) Third-party tank. Range: 0~6 EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 143
Domestic hot water pump g Heater element h Non-return valve INFORMATION The correct domestic hot water default settings become only applicable when domestic hot water operation is activated ([E‑05]=1). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 144
Set to Ecological, the heat source will be selected based on ecological parameters, resulting in a minimisation of primary energy consumption. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 145
10°C. See the user reference guide and/or operation manual for more details about this function. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 146
[7.7.1.1] [1‑00] Set weather-dependent heating: [1‑01] [1‑02] [1-02] [1‑03] [1-03] [1-00] [1-01] ▪ : Target leaving water temperature (main) ▪ : Outdoor temperature continued >> EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 147
If... Then the main pump runs... Space heating is done by... And... Outdoor unit only [C-0B]=1 According to ΔT control (see below). [C-0B]=0 At maximum pump speed. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 148
Leaving water temperature maximum modulation: Range: 0°C~10°C Requires modulation to be enabled. This is the value by which the desired leaving water temperature is increased or lowered. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 149
(set by the user interface) for under floor loops is 35°C. In such case, the unit will be controlled to realize a temperature difference of 5°C which means EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 150
During disinfection of the domestic hot water tank, the DHW temperature can exceed this maximum temperature. INFORMATION Limit the maximum hot water temperature according to the applicable legislation. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Preset leaving water temperature for the main leaving water temperature zone in case of NOT weather dependent [7.4.2.1] [8-09] Comfort (heating) [9‑01]°C~[9‑00]°C [7.4.2.2] [8-0A] Eco (heating) [9‑01]°C~[9‑00]°C EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 152
This function defines how much the water temperature may rise above the desired leaving water temperature before the compressor stops. The compressor will startup again when the leaving water temperature drops below the desired leaving water temperature. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 153
Temperature ranges (room temperature) ONLY applicable in room thermostat control. In order to save energy by preventing overheating the room, you can limit the range of the room temperature. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 154
Set the room antifrost temperature ([2‑05]). External room thermostat control Allow for the external room thermostat ([C‑07]=1) to take care of room frost protection: ▪ Turn leaving water temperature home page. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 155
ON on the user interface, and the auto emergency setting ([A.6.C]) is set to "1". Additionally, limited frost protection by the unit is possible: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 156
Additionally, a storage stop can be programmed. This feature puts a stop to tank heating even if the setpoint has NOT been reached. Only program a storage stop when tank heating is absolutely undesirable. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 157
(according to the weather-dependent curve). During weather-dependent operation, the end-user cannot adjust the desired tank temperature on the user interface. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 158
The disinfection function disinfects the domestic hot water tank by periodically heating the domestic hot water to a specific temperature. CAUTION The disinfection function settings MUST be configured by the installer according to the applicable legislation. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 159
This maximum allowable hot water temperature shall be selected according to the applicable legislation. CAUTION Make sure that the disinfection function start time [A.4.4.3] with defined duration [A.4.4.5] is NOT interrupted by possible domestic hot water demand. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 160
However, the disinfection function will be activated ONLY if the user confirms emergency operation via the user interface. Bivalent Only applicable in case of third-party gas boiler. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 162
▪ [F-03] Bottom plate heater hysteresis: defines the temperature difference between bottom plate heater ON temperature and the bottom plate heater OFF temperature. Bottom plate heater EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 163
Code Description [A.5.2.3] [8-0E] Boiler only ambient temp When the ambient temperature is lower than this temperature, the heat pump is NOT allowed to work. Range: –14°C~25°C EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 164
(because the heat exchanger coil is not operational) with a warmer top layer. Range: 0°C~20°C EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 165
2: 24 hours ▪ 3: 48 hours ▪ 4: 72 hours Offset temperature external outdoor ambient sensor Only applicable in case of an external outdoor ambient sensor is installed and configured. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 166
Pump speed limitation [9‑0D] defines the maximum pump speed. In normal conditions, the default setting should NOT be modified. The pump speed limitation will also be overruled when delta T is abnormal. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 167
The maximum values depend on the unit type: [9-0D]=0 [9-0D]=1/5 a (kPa) a (kPa) b (l/min) b (l/min) [9-0D]=2/6 [9-0D]=3/7 a (kPa) a (kPa) b (l/min) b (l/min) EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 168
Configuration [9-0D]=4/8 a (kPa) b (l/min) a External static pressure b Water flow rate EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Set weather-dependent heating (*) Only applicable in case of EHY2KOMB28+32AA gas boiler INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Actuator test run (*) Only applicable in case of EHY2KOMB28+32AA gas boiler. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/ invisible. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
If there is no need for immediate hot water delivery, the domestic hot water comfort function can be turned off. To reset the gas boiler INFORMATION Resetting is only possible when an error occurs. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 172
INFORMATION ▪ Press the button to exit the menu without storing the parameter changes. ▪ Press the button to load the default settings of the gas boiler. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 173
Use the user interface instead. Maximum supply temperature 30°C~90°C 90°C Do NOT modify this setting on of the heat curve the boiler. Use the user interface instead. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Minimal domestic hot water 23%~50% Adjustment range 23~50% (40=propane). (not applicable for It is recommended not to Switzerland) modify this setting in case of natural gas. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 175
Number of eco days. Anti-cycling period during 0 min~15 min 5 min Minimal switch-off time in space heating operation space heating operation. It is recommended not to modify this setting. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 176
Minimum required flow rate values for corresponding set powers are given in the table below. Minimum flow rate (l/ Set power (kW) min) 5.4 kW 8.5 kW 17.8 kW 12.5 26.2 kW EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 177
13 Put a sticker indicating the new gas type next to the gas valve, over the existing one. 14 Put the front panel back in its place. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 178
2 Switch off the gas boiler with the button. appears on the service display. 3 Remove the front panel from the gas boiler. 4 Remove the sampling point (a) and insert a suitable flue gas analyser probe. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 179
10 Allow readings to stabilise. Wait for at least 3 minutes and compare the CO percentage with the values in the table below. value at maximum power Natural gas Natural gas Propane P G31 Maximum value EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 180
(%) at minimum power power (front cover opened) Natural gas 2H/2E Propane 3P (G31, (G20, 20 mbar) 30/50/37 mbar) 10.8 — 10.5±0.1 10.6 10.3±0.1 10.4 10.1±0.1 10.2 9.9±0.1 10.0 9.8±0.1 9.6±0.1 EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 181
CO percentage at maximum power, contact your local dealer. 6 Press and simultaneously to exit the test program. 7 Put the front panel back in its place. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
INFORMATION For EHY2KOMB28+32AA, prolonged instant domestic hot water operation at low outdoor temperatures might be temporarily interrupted to protect the outdoor unit and water piping from freezing. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
When the temperature drops too fast and the anti-cycle time has passed, the shutdown will be cancelled. Self-test The sensors check the boiler controller. During the check-up, the boiler controller does NOT perform any other tasks. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 184
The space heating supply temperature must be set on the user interface of the hybrid module. See the user reference guide for more details. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Service Interval Record and left with the householder. 13.1 Overview: Commissioning This chapter describes what you have to do and know to commission the system after it is installed and configured. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
▪ Between the gas boiler and the local supply panel ▪ Between the outdoor unit and the gas boiler (bivalent signal) ▪ Between the outdoor unit and the external pump EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
To perform an actuator test run. To perform (start) an underfloor screed dryout (if necessary). To perform a gas pressure test. To perform a test run on the gas boiler. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
> Commissioning > Air purge > Start air purge and press to start the air purge function. Result: The manual air purge starts and the following screen appears. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
"To set the user permission level Installer" [ 137]. 2 Go to [A.7.1]: > Installer settings > Commissioning > Test run. 3 Select a test and press . Example: Heating. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Bottom plate heater test ▪ Bivalent signal test (in case of third-party gas boiler) ▪ Circulation pump test ▪ Gas boiler test (in case of EHY2KOMB28+32AA gas boiler) EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
The installer can program up to 20 steps. For each step he needs to enter: 1 the duration in hours, up to 72 hours, 2 the desired leaving water temperature, up to 55°C. Example: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 192
Result: The underfloor heating screed dryout starts and following screen will be shown. It stops automatically when done. To stop it manually, press , select OK and press EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
6 Modify and restart the execution of the program. 13.4.5 To perform a gas pressure test 1 Connect a suitable gauge on the gas valve. Static pressure MUST be 20 mbar. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Burner ON at minimum power Burner ON, maximum and (1×) space heating power setting Burner ON, maximum and (2×) domestic hot water setting Stop test program Actual situation EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 195
Commissioning NOTICE If an 81‑04 error occurs, then do NOT perform a test run on the gas boiler. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Show the user what to do for the maintenance of the unit. ▪ Explain about energy saving tips to the user as described in the operation manual. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
15.3.2 Checklist for yearly maintenance of the outdoor unit Check the following at least once a year: ▪ Heat exchanger ▪ Water pressure ▪ Water filter ▪ Water pressure relief valve EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 198
Water coming out of the valve may be very hot. ▪ Check if nothing blocks the water in the valve or in between piping. The water flow coming from the relief valve must be high enough. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
79]. 15.4.2 To disassemble the gas boiler 1 Turn off the appliance. 2 Turn off the main power supply of the appliance. 3 Close the gas tap. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 200
8 Pull the bottom of the pipe forwards and remove the pipe downwards by turning the pipe alternately clockwise and counterclockwise. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 201
9 Lift the condensate drain pan on the left-hand side from the connection to the condensate trap. 10 Turn it to the right with the condensate trap connection over the edge of the base tray. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
1 Clean the heat exchanger from top to bottom with a plastic brush or compressed air. 2 Clean the underside of the heat exchanger. 3 Clean the condensate drain pan with water. 4 Clean the condensate trap with water. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Make sure in doing this that the back of the condensate drain pan comes to rest on the lug of the back of the base tray. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 204
17 Fit the casing, tighten the 2 screws on the left and right side of the display. 18 Close the display cover. 19 Check the heating and hot water supply. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
16.3 General guidelines Before starting the troubleshooting procedure, carry out a thorough visual inspection of the unit and look for obvious defects such as loose connections or defective wiring. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Make sure that the water volume in the too low installation is above the minimum required value (see "9.3.4 To check the water volume and flow rate" [ 73]). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
(see "9.3.4 To check the water volume and flow rate" [ 73] and "9.3.5 Changing the pre-pressure of the expansion vessel" [ 73]). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
[A.8] > Installer settings > Overview settings [5‑01] There is air in the system. Purge air manually or automatically. See the air purge function in the "Commissioning" chapter. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Corrective action Boiler/hydrobox mismatch Make sure that the . setting is set to 0. Incompatibility of software Update the boiler and hydrobox software to the latest version. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Gas supply pressure too low. The house pressure switch may be faulty. Contact the gas company. Recirculation of combustion gasses. Check the flue gas and the air supply. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
16.4.17 Symptom: No domestic hot water Not applicable for Switzerland Possible causes Corrective action The burner is NOT firing on domestic Replace S3. hot water: S3 faulty. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Open the outdoor unit (see "10.2.2 To open the outdoor unit" [ 78]). The following illustration indicates the location of the outdoor unit LED on the PCB: EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
INFORMATION See the service manual for: ▪ The complete list of error codes ▪ A more detailed troubleshooting guideline for each error EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
OU: Voltage/current sensor problem. Please contact your dealer. OU: Malfunction of high pressure switch (HPS) Please contact your dealer. OU: Malfunction of position detection sensor. Please contact your dealer. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 215
Please contact your dealer. OU: Malfunction of inverter radiating fin temperature rise. Please contact your dealer. OU: Inverter instantaneous overcurrent (DC). Please contact your dealer. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 216
Please contact your dealer. Heat exchanger frozen. Heat exchanger frozen. Heat exchanger frozen. Abnormal increase outlet water temperature (DHW). Abnormal increase outlet water temperature. Overheating water circuit (thermostat). EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 217
Tank preheating External temperature sensor problem. Please contact your dealer. Tank temperature sensor problem. Please contact your dealer. Boiler abnormality detection Check boiler Refer to boiler manual EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 218
Error codes of the gas boiler The controller on the gas boiler detects faults and indicates them on the display by error codes. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 219
Fan catching on casing ▪ Wiring between fan and casing ▪ Check wiring for poor wire contact ▪ Replace fan 29, 30 Gas valve relay fault Replace boiler controller EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
4 Check on the manifold if the vacuum is reached. 5 After ±5 minutes, close the gas stop valve, and stop the pump down operation by pressing on the user interface. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 221
Disposal a Liquid stop valve b Closing direction c Hexagonal wrench d Valve cap e Gas stop valve EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Technical data 18 Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of the latest technical data is available on the Daikin Business Portal (authentication required). 18.1 Outdoor unit 18.1.1 Piping diagram: Outdoor unit...
Page 223
Technical data l Vacuum breaker EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
▪ Selecting a flow outside the operating area can damage the unit or cause the unit to malfunction. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Domestic hot water sensor S3 q Condensate S3 r Heat exchanger s Operating panel and read-out t Ionisation/ignition electrode u Position of data plate Bottom view EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Efficiency space heating (net calorific value 37/30 107.9% 108.3% (30%)) η30 Operation range 30~90°C Pressure drop See ESP curve in the installer reference guide. Maximum space heating water pressure (PMS) 3 bar EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 233
Boiler water volume 3.6 l 4.0 l Space heating water circuit Space heating piping connections Ø22 mm Piping material Copper Safety valve Not included Index 'x' only valid for DE. EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Page 234
Heat rated output (P 23 kW 27 kW rated Annual energy consumption (Q 47 GJ 53 GJ Seasonal space heating efficiency (η Sound power level indoors (at maximum heat output) (L Declared load profile EJHA04AAV3 + EHY2KOMB28+32AA Installer reference guide Daikin Altherma H Hybrid 4P531180-1D – 2025.03...
Optional equipment Equipment made or approved by Daikin that can be combined with the product according to the instructions in the accompanying documentation. Field supply Equipment NOT made by Daikin that can be combined with the product according to the instructions in the accompanying documentation.
Field settings table Applicable indoor units EHY2KOMB28AA EHY2KOMB32AA NHY2KOMB28AA NHY2KOMB32AA Notes — 4P564438-1 - 2018.12...
Page 240
Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value User settings └─ Preset values └─ Room temperature 7.4.1.1 Comfort (heating) [3-07]~[3-06], step: A.3.2.4 21°C 7.4.1.2 Eco (heating) [3-07]~[3-06], step: A.3.2.4 21°C └─...
Page 241
Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value A.3.1.1.1 LWT setpoint mode 0: Fixed 1: Weather dep. 2: Fixed / scheduled 3: WD / scheduled A.3.1.1.2.1 [9-01] Temperature range Minimum temp (heating) 15~37°C, step: 1°C...
Page 242
Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value A.6.D Disable protections 0: No 1: Yes └─ Overview settings [0-00] 35°C [0-01] 55°C [0-02] 15°C [0-03] -10°C [0-04] 8°C [0-05] 12°C...
Page 243
Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [5-03] [5-04] [5-05] 50 A [5-06] 50 A [5-07] 50 A [5-08] 50 A [5-09] 20 kW [5-0A] 20 kW [5-0B] 20 kW [5-0C]...
Page 244
Installer setting at variance with Field settings table default value Breadcrumb Field code Setting name Range, step Date Value Default value [C-04] Bivalent hysteresis temperature. 2~10°C, step 1°C 3°C [C-05] What is the thermo request contact type for the main zone? 1: Thermo ON/OFF 2: C/H request [C-06]...
Need help?
Do you have a question about the Altherma H Hybrid EJHA04AAV3 and is the answer not in the manual?
Questions and answers