Item
Description
13
System fan 1
14
Online spare
memory
15
Memory mode

System LEDs and internal health LED combinations

When the internal health LED on the front panel illuminates either amber or red, the server is experiencing
a health event. Combinations of illuminated system LEDs and the internal health LED indicate system
status.
The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may
report server status differently than the health LEDs because the software tracks more system attributes.
System LED and color
Processor failure,
socket X (amber)
Processor failure, both
sockets (amber)
PPM failure (amber)
FBDIMM failure, slot
X (amber)
Overtemperature
(amber)
Fan (amber)
Status
Amber = Fan is not installed or has failed
Off = Rear fan is functioning
Amber = Online spare memory is in use due to
memory failover
Off = Normal operation
Green = System is in online spare memory
mode
Off = Normal operation
Internal health LED
Status
color
Red
One or more of the following conditions may exist:
Processor in socket X has failed.
Processor in socket X failed over to the second
processor.
Processor X is not installed in the socket.
Processor X is not supported.
Processor heatsink is not attached properly.
Amber
Processor in socket X is in a pre-failure condition.
Red
Processor types are mismatched.
Red
PPM has failed.
PPM is not installed, but the corresponding processor
is installed.
Red
FBDIMM in slot X has failed.
FBDIMM in slot X is an unsupported type, and no
valid memory exists in another bank.
Amber
FBDIMM in slot X has reached single-bit correctable
error threshold.
FBDIMM in slot X is in a pre-failure condition.
FBDIMM in slot X is an unsupported type, but valid
memory exists in another bank.
Red
The Health Driver has detected a cautionary
temperature level.
The server has detected a hardware critical
temperature level.
Red
The minimum fan requirements are not being met. Fan has
failed.