Zoned And Shared Storage-To The Same C-Class Enclosure - HP 2000sa Deployment Manual

Hp direct-connect external sas storage for hp bladesystem solutions deployment guide
Hide thumbs Also See for 2000sa:
Table of Contents

Advertisement

Zoned and Shared storage—to the same c-Class enclosure
This example illustrates cabling from one BladeSystem c-Class enclosure to both an MSA2000sa
G2 controller enclosure and an MDS600 storage enclosure. In this type of configuration, note the
following:
IMPORTANT:
In a solution with both zoned and shared storage enclosures, a server bay can be assigned
to either zoned or shared zone groups. (Cannot be assigned to both types of storage
enclosures.)
The MSA2012sa is not supported for use in this configuration.
1 10
Deployment examples
Devices and quantities
MSA2300sa controller enclosures: 1
MSA2000 drive enclosures: 3
MDS600 storage enclosures: 1
c7000 enclosures: 1
3Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
Switch in interconnect bay 5:
◦ Port 1: to MSA G2 SAS port A1
◦ Port 2: to MSA G2 SAS port B1
◦ Port 3: to MDS600 drawer 2, primary
I/O module, port 1
◦ Port 4: to MDS600 drawer 2, primary
I/O module, port 2
◦ Port 7: to MSA2000sa drawer 1,
primary I/O module, port 1
◦ Port 8: to MDS600 drawer 1, primary
I/O module, port 2
Switch in interconnect bay 6:
◦ Port 1: to MSA G2 SAS port A1
◦ Port 2: to MSA G2 SAS port B1
◦ Port 3: to MDS600 drawer 2,
secondary I/O module, port 1
◦ Port 4: to MDS600 drawer 2,
secondary I/O module, port 2
◦ Port 7: to MSA2000sa drawer 1,
secondary I/O module, port 1
◦ Port 8: to MDS600 drawer 1,
secondary I/O module, port 2
Notes
As shown in this illustration, server bays
1–8 may access MDS600 drawer 2 and
server bays 9–16 may access MDS600
drawer 1. For more information, see
3Gb SAS BL Switch port information"
(page
83).
"HP

Advertisement

Table of Contents
loading

Table of Contents