Msa2000Sa Family Storage Enclosure Installation Notes And Best Practices - HP 2000sa Deployment Manual

Hp direct-connect external sas storage for hp bladesystem solutions deployment guide
Hide thumbs Also See for 2000sa:
Table of Contents

Advertisement

During the updating process, firmware on the primary and secondary MDS600 I/O
modules are automatically updated (assuming both I/O modules are attached to a pair
of SAS switches in the same BladeSystem interconnect row.)
For more information about updating MDS600 firmware, see the HP3G Virtual SAS
Manager User Guide.

MSA2000sa family storage enclosure installation notes and best practices

You can specify a nickname (host name) for the SAS WWN to be able to easily identify the
host in the host list.
For the MSA2000sa, see set host-wwn-name in the HP StorageWorks 2000 Family
Modular Smart Array CLI reference guide or "Managing the Global Host List on a SAS
System" in the HP StorageWorks 2000 Family Modular Smart Array reference guide.
For the MSA2000sa G2, see set host-name in the HP StorageWorks 2000 G2 Family
Modular Smart Array CLI reference guide or "Managing the Global Host List on a SAS
System" in the HP StorageWorks 2000 G2 Family Modular Smart Array reference guide.
If creating multiple volumes, consider using multiple Vdisks to improve performance.
Decide whether to use explicit mapping to control which hosts can access a volume. For more
information, see "Managing Host Access to Volumes" in the HP StorageWorks 2000 Family
Modular Smart Array reference guide.
Use blanks to fill unpopulated drive bays. Gaps between components cause changes in airflow
through the device. Using blanks ensures proper airflow.

MSA2000sa family storage enclosure installation notes and best practices

57