Installation Notes And Best Practices; Bladesystem C-Class Enclosure Installation Notes And Best Practices; Server Blade Installation Notes And Best Practices; Hp P700M Controller Installation Notes And Best Practices - HP 2000sa Deployment Manual

Hp direct-connect external sas storage for hp bladesystem solutions deployment guide
Hide thumbs Also See for 2000sa:
Table of Contents

Advertisement

6 Installation notes and best practices

BladeSystem c-Class enclosure installation notes and best practices

The BladeSystem c-Class enclosure can be installed in a rack or rack-free environment.
Before installing components in the BladeSystem c-Class enclosure, be sure to review enclosure
device bay and interconnect bay numbering.
Before installing components in the BladeSystem c-Class enclosure, be sure understand which
mezzanine slots on which servers map to which interconnect bay.

Server blade installation notes and best practices

Before installing the server blades in the BladeSystem c-Class enclosure, be sure to install one
P700m Controller on each server blade.
Before installing server blades in the BladeSystem c-Class enclosure, be sure to understand
the mapping relationships between server mezzanine slots, BladeSystem enclosure server
device bays, and BladeSystem enclosure switch interconnect bays. For more information, see
"Zoning requirements and device mappings" (page
When assigning drive-bay based zone groups to a server, the server blades may need to first
be taken offline. Restart them after completing the assignments and saving all changes in the
VSM interface. For more information, see
(page 39)

HP P700m Controller installation notes and best practices

In zoned solutions such as those using the MDS600 storage enclosure, the 512 MB model
HP P700m Controller is required. In addition, for RAID 6 support, the battery option kit is
required.
The choice of mezzanine slot in which the P700m Controller is installed determines the
BladeSystem interconnect bay in which you must install the SAS BL Switches, because each
mezzanine slot maps to a specific interconnect bay of the BladeSystem c-Class enclosure. For
more information, see
New HP ProLiant server blades auto-configure when they are powered up for the first time.
For more information about the Auto configuration process, see the server-specific setup and
installation guide or the HP ROM-Based Setup Utility User Guide. These guides are available
on the server Documentation CD.
Do not power up the server until the hardware configuration is satisfactory and remember to
check the HP P700m Controller website for the latest firmware version and upgrade.
.
"Zoning requirements and device mappings" (page
39)..
"Zoning requirements and device mappings"

BladeSystem c-Class enclosure installation notes and best practices

39).