Shared storage—dual controller, standard cabling
This example illustrates standard cabling for a high-availability configuration. In this configuration,
note the following:
One cable from each switch to each MSA controller offers high availability.
NOTE:
Features of the MSA2000sa and MSA2000sa G2 differ, but cabling and configuration
concepts are the same. This cabling scenario showing the MSA2000sa may also be applied to
the MSA2000sa G2.
NOTE:
Connections to a dual-controller MSA2000sa G2, are very similar to that of the
MSA2000sa: connect the first SAS port of the primary MSA controller (SAS port A1) to one of the
switches, and connect the secondary MSA controller (SAS port B1) to the other switch.
102 Deployment examples
Devices and quantities
MSA2000sa controller enclosures: 1
MSA2000 drive enclosures: 0
BladeSystem c7000 enclosures: 1
3Gb SAS BL Switches: 2
Server blade types: half-height and full-height
Connection details
Switch in interconnect bay 5:
◦ Port 1: to MSA SAS port A0
Switch in interconnect bay 6:
◦ Port 1: to MSA SAS port B0
Notes
If additional ports on the MSA controllers
or 3Gb SAS BL Switch are available, HP
recommends connecting an additional
cable from the switch to the MSA
controllers, for additional performance and
fault tolerance. For an example, see
"Shared storage—dual controller, optimal
cabling, MSA2000sa" (page 103)