3
Track and control switch changes
3. Verify the threshold settings you have configured for each parameter.
Example output from a switch
The following example displays what is typically seen from a Brocade 300, 4100, 4900, 5000,
5410, 5424, 5450, 5460, 5470, 5480, 5100, 5300, 5424, 7500, 7500E, 7600, 7800, 8000, and
a VA-40FC switch, but the quantity and types vary by platform.
58
The current switch status policy parameter values are displayed. You are prompted to enter
values for each DOWN and MARGINAL threshold parameter.
NOTE
By setting the DOWN and MARGINAL values for a parameter to 0,0 that parameter is no longer
used in setting the overall status for the switch.
Enter the switchStatusPolicyShow command to view your current switch status policy
configuration.
switch:admin> switchstatuspolicyset
To change the overall switch status policy parameters
The current overall switch status policy parameters:
Down
----------------------------------
PowerSupplies
Temperatures
Fans
WWN
CP
Blade
CoreBlade
Flash
MarginalPorts
112
FaultyPorts
112
MissingSFPs
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
The minimum number of
Bad PowerSupplies contributing to DOWN status: (0..4) [3]
Bad PowerSupplies contributing to MARGINAL status: (0..4) [0]
Bad Temperatures contributing to DOWN status: (0..32) [2]
Bad Temperatures contributing to MARGINAL status: (0..32) [1]
Bad Fans contributing to DOWN status: (0..3) [2]
Bad Fans contributing to MARGINAL status: (0..3) [1]
Down
WWN contributing to DOWN status: (0..2) [0]
Down
WWN contributing to MARGINAL status: (0..2) [1]
Down CP contributing to DOWN status: (0..2) [0]
Down CP contributing to MARGINAL status: (0..2) [1]
Down Blade contributing to DOWN status: (0..8) [0]
Down Blade contributing to MARGINAL status: (0..8) [1]
Down CoreBlade contributing to DOWN status: (0..2) [0]
Down CoreBlade contributing to MARGINAL status: (0..2) [1]
Out of range Flash contributing to DOWN status: (0..1) [0]
Marginal
3
0
2
1
2
1
0
1
0
1
0
1
0
1
0
1
44
44
0