R-Net Link In/Out - Russound CAV66 2 Instruction Manual

6-zone, 6-source audio/video controller amplifier
Table of Contents

Advertisement

R-NET Link In and Link Out
The R-NET Link In and Link Out is used to con-
nect two or more CAV6.6 controllers. The con-
nection is made using a CAT-5 patch cable from
the Link Out of the master CAV6.6 and into the
Link In of the next CAV6.6. Along with R-NET
data signals, the R-NET Link In and Link Out jack
passes the six source IR signals. These are only
for source-specific IR remote repeating, not
codes initiated from the controller's internal IR
library. The CAT-5 patch cable should not
exceed 18 inches in length to avoid potential
cross-talk between the source-specific IR repeat-
ing signal lines.
MAKING CONNECTIONS
Note: If two or more CAV6.6 controllers will be
connected using the R-NET Link In and Link Out
ports, each controller must have a unique
Controller ID (see Controller Setup - Flow
Chart on page 65) prior to being connected
through the R-NET ports. The Controller ID
assignment must be performed during the
Controller Setup section of the Installation menu.
The R-NET Link In and Link Out is also used to
connect the CAV6.6 to other Russound products
with R-NET.
INSTALLER
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cav6.6-s2

Table of Contents