Getting Started; Unpacking; System Components; Tools Needed - Russound CAV66 2 Instruction Manual

6-zone, 6-source audio/video controller amplifier
Table of Contents

Advertisement

INSTALLER

GETTING STARTED

Unpacking the System Components
• Keep the original carton and packing materials
for future shipment or storage.
• Check for any visible signs of damage. If
you encounter any concealed damage, con-
sult your Russound dealer before proceeding
to install the unit.
• Retain the sales receipt as it establishes the
duration of the limited warranty and provides
information for insurance purposes.
CAV6.6-S2 System Components:
• 1 (one) CAV6.6 Controller/Amplifier
• 6 (six) UNO-S2 System Control Keypads
• 1 (one) UNO-LRC1 Learning/Preprogrammed
Remote Control
• 6 (six) 845.1 Micro Emitters
Tools needed for installation:
• Drill with a 1/2" x 6" drill bit
• Keyhole saw
• Flat head screwdriver (medium size)
• Phillips Screwdriver (cordless recommended)
• 110 punchdown tool (included)
• Modular RJ-45 crimper and connectors
• Pair of diagonal cutters or wire strippers
• Stud finder
• Steel wire fish tape
• Cable staples
• Double-gang electrical work boxes

System Installation Considerations

There are several factors to consider before
installing the Russound CAV6.6-S2 system:
16
• What are the intended listening zones, and
what zones require audio and video distribution
or audio only?
®
• Are A-BUS
sub-zones needed? A-BUS sub-
zones are only available for zones 1 - 4. The A-
KP2 amplified keypad can provide direct source
selection for only the first four sources when in
'Multi' source mode.
• What system options and accessories might
be required for features such as paging, local
sources, etc.?
• From where in each zone will the user prefer
to control the system? Where will the keypads
be located? Where will the speakers be located?
• Where will the source equipment be located?
The CAV6.6 must have proper ventilation above
and below for air circulation and heat dissipation.
A rack-mount location may require fans and vents.

Connection Tips

• It is recommended that the CAV6.6 and the
source equipment be plugged into a dedicated
20-amp circuit with an isolated ground. A power
line conditioner can reduce interference prob-
lems caused by noise found in some electrical
systems.
• Disconnect all live power cords before making
connections to the controller.
• Verify that all connections and polarity are
correct.
• Keep all power cords away from all signal
cables to prevent humming from induced noise.
• Choose reliable signal cables/patch cords.
• Label all wires with room location at both ends
of the wire.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cav6.6-s2

Table of Contents