Controller Setup - Russound CAV66 2 Instruction Manual

6-zone, 6-source audio/video controller amplifier
Table of Contents

Advertisement

INSTALLER
INSTALLATION MENU
Zone Setup (cont'd)
1. ZON VOL TRIM (f)
2. SYSON ENABLE(f)
3. PARTY ENABLE(f)
4. MASTER ENABLE(f)
5. PAGE ENABLE(f)
6. PAGE VOLUME(f)
CTRLR SETUP (m)
Controller Setup is the basic configuration of the controller. This setup menu selects the options for
Controller ID and Factory Initialization. See Installation Menu on Page 48 and Controller Setup -
Flow Chart on page 65
1. CONTROLLER ID (f)
2. FACTORY INIT (f)
54
This feature allows the installer to adjust the output volume to
each zone. -16 dB (lowest) to 0 dB (max)(default).
This feature is either disabled or enabled. If disabled (default), an
All On command activated from another zone will not turn on the
disabled zone. If enabled, an All On command activated from
another zone will turn on the enabled zone.
This feature is either disabled or enabled. If disabled, Party Mode
activation from another zone will not affect the disabled zone. If
enabled (default), the zone will participate with Party Mode.
This feature is either disabled or enabled. If disabled, the zone
cannot host a master keypad during Party Mode. If enabled
(default), the zone has the option of hosting the Master keypad.
This feature is either disabled or enabled. It allows the option of
receiving or blocking a page in a zone. If disabled, the page will
not be sent to the zone. If enabled (default), the page will be
sent to the zone.
This feature allows the installer to adjust the Page Volume for the
zone, from 0 (min) to 100 (max).
This defines the Controller ID for this system. The default is 1 but
when multiple controllers are used, each additional controller ID
must be sequential and unique and be set before being connect-
ed to the system. Note that the system must be restarted before
the controller will assume the new ID.
WARNING: This procedure returns the controller to its
original settings - use with discretion.
Factory Initialization allows the installer to erase all programmed
settings and returns the settings to the factory default settings.
All settings including source equipment IR commands will need to
be reentered. An "Are you sure?" prompt and a "no" response
allows the installer to cancel the reset; a "yes" at the prompt will
load factory/default settings.