12VDC Mute Trigger In
When 12VDC is applied to the Mute In, the
system will fully mute all zones in the system.
The connections for the trigger are made using a
two-conductor cable with 1/8" male mini-plug
jacks. The tip is positive (+) and sleeve is nega-
tive (-). This allows for the connection of an exter-
nal paging or muting device. Note: The CAS44
will not accept a paging audio input; however, if
used with an independent paging system with
12V trigger out, that can be used to trigger the
mute.
12VDC Power Supply

12VDC Mute Trigger In/Trigger Out

12VDC System Trigger Out
Trigger Out 12VDC output is used for triggering
an external amplifier or other component. The
connections for the output are made using a
two-conductor cable with 1/8" male mini-plug
jacks at each end. The tip is positive (+) and
sleeve is negative (-). The System Trigger Out
supplies 12VDC when the first keypad is turned
on. The 12 VDC is removed 5 minutes after the
last keypad is turned off.