Specifications; Environmental Specifications; Power Supply Specifications - HP AX691B Maintenance And Service Manual

User manual
Table of Contents

Advertisement

Specifications

Environmental specifications

Specification
Temperature range*
Operating
Shipping
Storage
Maximum wet bulb
temperature
Relative humidity
(noncondensing)**
Operating
Non-operating
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.

Power supply specifications

Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 1200 W Power Supply
Specification
Input requirements
Rated input voltage
Rated input frequency
Rated input current
Rated input power
BTUs per hour
Power supply output
Value
10°C to 35°C (50°F to 95°F)
-30°C to 50°C (-22°F to 122°F)
-30°C to 60°C (-22°F to 140°F)
28°C (82.4°F)
10% to 90%
5% to 95%
Value
100 to 120 VAC, 200 to
240 VAC
50 Hz to 60 Hz
10 A at 100 VAC
4.9 A at 200 VAC
930 W at 100V AC input
1348 W at 200V AC input
3530 at 120V AC input
4600 at 200V to 240V AC
input
Specifications 90