Remove the hot-plug power supply.
5.
WARNING:
the power cord to the power supply until the power supply is installed.
To replace the component:
Slide the hot-plug power supply into the power supply bay.
1.
Connect the power cord to the power supply.
2.
Install the cable management arm, if removed
3.
Route the power cord through the cable management arm or power cord anchor.
4.
NOTE:
that the redundant power supply can be removed without disconnecting the power cord from
the primary power supply.
Close the cable management arm.
5.
Connect the power cord to the power source.
6.
Be sure that the power supply LED is green
7.
Be sure that the power supply LED on the SID is green
8.

Optical drive

To remove the component:
CAUTION:
unless all bays are populated with either a component or a blank.
Power down the server (on page 25).
1.
Extend the server from the rack (on page 26).
2.
Remove the access panel
3.
To reduce the risk of electric shock or damage to the equipment, do not connect
If using the power cord anchor, be sure to leave enough slack in the power cord so
To prevent improper cooling and thermal damage, do not operate the server
("Access
panel" on page 30).
("Access the product rear
("Rear panel LEDs and
buttons" on page 79).
("Systems Insight Display
Removal and replacement procedures 33
panel" on page 27).
LEDs" on page 76).