Fop_Port And Fcu_Port Subclass Default Settings; Table 17 Fop_Port Subclass Default Settings - Brocade Communications Systems 8 Administrator's Manual

Supporting fabric os v6.4.0
Hide thumbs Also See for 8:
Table of Contents

Advertisement

FOP_Port and FCU_Port subclass default settings

The following table provides default settings for areas in the FOP_Port and FCU_Port subclasses.
Port fencing can only be enabled or disabled for the following areas for the FOP_Port and FCU_Port
class:
TABLE 17
Area
Class 3 Discards
Loss of
Synchronization
Count
Receive (Rx)
Performance
State Changes
Fabric Watch Administrator's Guide
53-1001770-01
Area: Class 3 (C3) Discards
Unlike the other areas, take a conservative approach for the C3 Discards area. Use the default
settings and configure the alarms for Above. The goal is to locate issues with the device or its
infrastructure, so monitor the data to help isolate issues. Port fencing is one of the
recommended solutions for isolating issues.
Area: Trunk Utilization
The Trunk Utilization area is new; therefore, recommended settings are not yet available. Use
the default settings, monitor the results, and adjust your settings accordingly.
Areas: Primitive Sequence Protocol Error, State Changes
These areas are not used for monitoring; therefore, leave the default alarm settings at 0.
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
Class 3 Discards
FOP_Port subclass default settings
Description
Class 3 discards
frames due to
timeout or
destination
unreachable.
Monitors the
number of loss of
synchronization
errors
Monitors the receive
rate, by percentage
Monitors state
changes
Port class guidelines and default settings
Default threshold
Default alarm settings
settings
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 5
In-Between: 0
Buffer: 0
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 500
In-Between: 0
Buffer: 50
Unit: Percentage (%)
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 100
In-Between: 0
Buffer: 0
Unit: Changes
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 50
In-Between: 0
Buffer: 0
7
Threshold state
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Out_of_range
In_range
65

Advertisement

Table of Contents
loading

Table of Contents