7
Port class guidelines and default settings

E_Port class default settings

Table 16
Port fencing can be enabled or disabled for the following areas for the E_Port class:
TABLE 16
Area
Class 3 Discards
Invalid CRC Count
Invalid Transmission
Words (ITW)
Link Failure Count
Loss of Signal Count
Link Reset
62
Areas: Primitive Sequence Protocol Error, State Changes, Utilization, Packet Loss
These areas are not used for monitoring; therefore, leave the default alarm settings at 0.
provides default settings for areas in the E_Port class.
Link Failure Count
Loss of Synchronization Count
Primitive Sequence Protocol Error
Invalid Transmission Word
Invalid CRC Count
E_Port class default settings
Description
Class 3 discards
frames due to
timeout or
destination
unreachable.
Monitors the
number of CRC
errors
Monitors the
number of invalid
words transmitted
Monitors the
number of link
failures
Monitors the
number of signal
loss errors
Monitors the
number of link
resets sent by a
given port (LR-Out)
and received on a
given port (LR-In).
Default threshold
Default alarm settings
settings
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 5
In-Between: 0
Buffer: 0
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 1000
In-Between: 0
Buffer: 100
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 1000
In-Between: 0
Buffer: 100
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 500
In-Between: 0
Buffer: 50
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 5
In-Between: 0
Buffer: 0
Unit: Errors
Changed: 0
Time Base: minute
Below: 0
Low: 0
Above: 0
High: 500
In-Between: 0
Buffer: 50
Threshold state
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range
Informative
Informative
Out_of_range
In_range