2
Time bases
Example 1: Triggering an event
Figure 4
the example). A high threshold of 2 is specified to trigger an event. A time base of minute is
defined. An event occurs only if the rate of change in the specific interval (one minute in this
example) is across the threshold boundary. It should be either higher than the high threshold limit
or lower than the low threshold limit.
As illustrated on the tenth sample, the counter value changes from 0 to 1; hence calculated rate of
change is 1 per minute. At the thirteenth sample, the rate of change is 2 per minute. The rate of
change must be at least 3 per minute to exceed the event-triggering requirement of 2, which is met
on the eighteenth sample.
FIGURE 4
Example 2: Not triggering an event
Figure 5
an event. In this case, the calculated rate of change in the data value is always less than or equal to
the high threshold of 2.
At the tenth sample, the rate of change is one per minute. At the fourteenth, twenty-first, and
twenty-fifth sample, the rate of change remains equal to the high threshold of 2. In this case, Fabric
Watch does not trigger an event even though the absolute value of the counter reaches 4, which is
well above the high threshold.