Specifying Triggers For Fru Alarms - Brocade Communications Systems 8 Administrator's Manual

Supporting fabric os v6.4.0
Hide thumbs Also See for 8:
Table of Contents

Advertisement

8
FRU monitoring
4. In the prompt that follows your current FRU configuration, you are asked to provide values for

Specifying triggers for FRU alarms

You can specify triggers for any number of alarm states or alarm actions. The first prompt enables
you to select which FRU states trigger events.
1. Add the numbers beside each state (for the states you want to include).
2. Enter the total at the prompt.
For example, to trigger events using the Absent, Off, and Faulty states, add the assigned values and
enter that value at the prompt. In this case, the values are 1, 8, and 16, respectively, and the total
is 25.
92
each FRU alarm state and alarm action. To accept the default value for each FRU, press
Return.
After you have configured a FRU alarm state and alarm action, the values apply to all FRUs of
that type. For example, the values specified for a slot FRU will apply to all slots in the enclosure.
swd123:admin> fwfrucfg
The current FRU configuration:
Alarm State
------------------------------------------------------
Slot
Power Supply
Fan
WWN
Note that the value 0 for a parameter means that it is NOT used in the
calculation
Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16
Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [31]
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [0]
Power Supply Alarm Action: (0..17) [0]
Fan Alarm State: (0..31) [0]
Fan Alarm Action: (0..17) [0]
WWN Alarm State: (0..31) [0]
WWN Alarm Action: (0..17) [0]
Fru configuration left unchanged
Alarm Action
31
0
0
0
1
0
0
0
Fabric Watch Administrator's Guide
53-1001770-01