Ness D16xD Installer Manual

Ness D16xD Installer Manual

Deluxe alarm control panel
Table of Contents

Advertisement

D8xD / D16xD AlArm Control PAnel
8
16
8 or 16
Auto-Time
Hardwired or
Automation
Wireless zones
easy
Fast
Programming
Programming
via Keypad
via PC
Installer Software
Installation & Programming Manual
Deluxe edition with expanded AUX outputs, Voice alarms,
Voice prompts, enhanced modem, Real time clock.
AUX
8 x AUX
Various
Operation by
Outputs
Keypad
Smartphone /
Options
Free
On-Site
Back To Base
NessComms
Programming
or Voice Dialler
via PD Tool
Monitoring
Available with Navigator, Saturn or
KPX keypad options
Operation by
Voice Alarms
Telephone
& Prompts
Internet
Adjustable
C-BUS
Vibration Inputs
Compatible
on all Zones
using Ness
MiniCentral
D8x/D16x DelUXe
Version v8.4
Access
Powerful
Control
Wireless
onboard
Options
Area
Dual Voltage
Partitioning
17VAC & 20VDC
Document 890-017
1.6
Rev

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D16xD and is the answer not in the manual?

Questions and answers

Summarization of Contents

What's New in D8x/D16x Deluxe (v8)
D8x/D16x All Features
Comprehensive list of features for the D8x/D16x control panel.
NESSCOMMS
MINI CENTRAL C-BUS
C-Bus interface for full two-way control of alarm panel.
NESS PD
Portable download tool for copying programming options.
ESD WARNING
INSTALLATION PROCEDURES
Step-by-step guide for physically installing the control panel.
POWER-UP PROCEDURE
Procedure for powering up the panel and entering installer mode.
INPUTS
MONITORED ZONES
Details on programmable zone inputs and end-of-line resistor termination.
END OF LINE RESISTOR
Explanation of EOL resistor values and programming options.
BATTERY
Specifications and connection details for the backup battery.
OUTPUTS
12 VOLT OUTPUT
Description of the regulated 13.8V DC output for detectors.
SIREN
Details on the on-board siren driver and load capacity.
RESET
Description of the 12V DC output for sirens, piezos, or relays.
CONNECTION DIAGRAMS
END OF LINE RESISTORS
Diagram illustrating EOL resistor wiring for zones.
ZONE WIRING
Diagrams showing N.C. and N.O. device wiring for zones.
Optional Accessories for D8 & D16
Generic Detector Wiring Examples
Wiring examples for hardwired detectors and LUX HW detectors.
Siren Wiring Examples
Wiring examples for connecting sirens and strobe lights.
KEYPAD
KEYPAD DISPLAY INDICATORS IN OPERATING MODE
Explains the meaning of keypad icons during normal operation.
KEYPAD BEEPS
Defines the different keypad beep signals and their meanings.
OPERATION
OPERATION SUMMARY
Summary of how to arm, disarm, and operate the system via keypad, radio, or card.
PROGRAMMING
QUICK START 1 - LOCAL SYSTEM, SIMPLY PROGRAM A USER CODE
Steps for programming a basic user code for local systems.
QUICK START 2 - AUDIBLE MONITORING
Steps for configuring audible monitoring and telephone numbers.
SPECIAL FUNCTIONS IN PROGRAM MODE
Details on special programming functions like tests and resets.
PROGRAMMING
HOW TO ENTER PROGRAM MODE
Methods for entering installer and user program modes.
HOW TO PROGRAM A PANEL USING NESS PD
Guide for using the Ness PD tool to copy programming data.
USER CODES
KEYPAD (PIN) CODES
Details on programming, deleting, and using keypad PIN codes.
ARM ONLY CODES
How to configure user codes that can only arm the system.
USER CODES
ASSIGNING EXTRA OPTIONS
How to assign Area, Arm Only, Radio Code, and Reader Code options.
PROGRAMMING
ENTRY DELAY TIME 1
Setting the delay time for initial entry.
ENTRY DELAY TIME 2
Setting the delay time for a second entry point.
EXIT DELAY TIME
Setting the time allowed to arm and leave the premises.
SIREN RESET TIME
Setting the duration for siren and reset outputs.
VIBRATION SENSITIVITY
ADJUSTING NESSENSORS
Guidance on adjusting Nessensor sensitivity for optimal detection.
LONG RESPONSE ZONES
Setting zones for a longer reaction time for REX inputs.
ZONE DELAY TYPES
DOUBLE TRIGGER ZONES
Configuring zones to require two triggers for an alarm.
INSTANT ZONES
Configuring zones to trigger alarms immediately when armed.
ENTRY DELAY1 ZONES
Configuring zones to activate the Entry Delay Timer when triggered.
AREA PARTITIONING
ASSIGNING ZONES TO AREAS
Assigning zones to Area 1, Area 2, or both for partitioning.
AREA PARTITIONING & HOME MODE
HOME MODE
Configuring selective arming of zones while at home.
TEMPORARY DAY ZONES
Allowing users to select day zones temporarily via keypad.
AUX 2 OPTION
Using Aux 2 for day zone warnings when temporary day zones are enabled.
PROGRAMMING
HOME ZONES
Configuring zones to be armed in Home Mode.
24hr ZONES
Configuring zones to operate at all times, regardless of system state.
DAY ZONES
Configuring zones to trigger alarms only when the panel is disarmed.
PROGRAMMING
ZONE TO OUTPUT MAPPING
Selecting which zones trigger Sonalert, Strobe, Siren, Reset, AUX1, AUX2.
RESET OUTPUT ZONES
Selecting zones that trigger the Reset output.
STROBE OUTPUT ZONES
Selecting zones that trigger the Strobe output.
KEYPAD SONALERT ZONES
Selecting zones that sound the Keypad Sonalert.
PROGRAMMING
SIREN OUTPUT ZONES
Selecting zones to trigger the Siren output.
AUX1,3 OUTPUT ZONES
Selecting zones to trigger AUX1 or AUX3 outputs.
AUX2,4 OUTPUT ZONES
Selecting zones to trigger AUX2 or AUX4 outputs.
PROGRAMMING
ENTRY BEEPS
Enabling or disabling keypad beeps during entry delay.
KEYSWITCH OPERATION
Configuring keyswitch use for arming, disarming, or home mode.
PROGRAMMING
TAMPER SIREN LOCKOUT
Programming the tamper input to cause siren/reset lockout.
DURESS TO RESET OUTPUT
Triggering the reset output when a duress alarm occurs.
AUTO EXCLUDE ZONES
Automatically excluding zones unsealed at exit time.
DISABLE THE DISPLAY
Configuring the keypad display to blank after inactivity.
DELAYED AUX3 & AUX4 OUTPUTS
Setting delayed activation for AUX3 and AUX4 outputs upon arming.
PROGRAMMING
TAMPER ALARM / OUTPUT MAPPING
Selecting which outputs trigger on a tamper alarm.
KEYPAD PANIC ALARM / OUTPUT MAPPING
Selecting which outputs trigger on a keypad panic alarm.
PROGRAMMING
SYSTEM OPERATION SHORTCUTS
Enabling keypad shortcuts for common operations.
SIREN BURST ON AUTO EXCLUDE
Enabling a siren burst to indicate auto-excluded zones.
EXIT TIME X10
Multiplying the exit delay time by a factor of 10.
PROGRAMMING
HOME MODE OUTPUT MAPPING
Selecting which outputs trigger on Home Mode alarms.
DAY MODE OUTPUT MAPPING
Selecting which outputs trigger on Day Mode alarms.
PROGRAMMING
BRIEF HOME MODE ALARM
Setting home mode alarms to trigger outputs for 2 seconds.
BRIEF DAY ALARM
Setting day mode alarms to trigger outputs for 2 seconds.
HOME ZONES ENTRY DELAY 2
Assigning Entry Delay 2 to all Home zones.
ARM/DISARM CHIRPS
Enabling siren chirps for arming/disarming via keyswitch or radio key.
PROGRAMMING
STROBE FLASH ON HOME ARMING BY RADIO
Enabling strobe flash for home mode arming by radio key.
SUPERVISED ZONES
Supervision for HARDWIRED ZONES
Setting supervision for wired zones to detect inactivity.
Supervision for RADIO ZONES
Setting supervision for radio devices to detect loss of signal.
PROGRAMMING
ZONE SUPERVISION ALERTS – RESET OUTPUT
Setting reset output alerts for supervised zone alarms.
ZONE SUPERVISION ALERTS – STROBE OUTPUT
Setting strobe output alerts for supervised zone alarms.
ZONE SUPERVISION ALERTS - KEYPAD SONALERT
Setting keypad sonalert alerts for supervised zone alarms.
ZONE SUPERVISION ALERTS – SIREN OUTPUT
Setting siren output alerts for supervised zone alarms.
PROGRAMMING
ENABLE WIRED ZONE SUPERVISION
Enabling supervision for wired or radio zones.
SUPERVISION TIME SPEEDUP X6
Speeding up supervision time by a factor of 6.
SUPERVISION TIME SPEEDUP X10
Speeding up supervision time by a factor of 10.
SUPERVISION TIME
Setting the time interval before a supervised zone triggers an alarm.
PROGRAMMING
DOUBLE PRESS RADIO PANIC
Enabling double press panic for radio keys.
AUTO RE-ARM
Automatically re-arming the system after disarming if zones remain sealed.
LONG RADIO MESSAGE
Enabling longer radio messages for enhanced security.
PROGRAMMING
"OK/READY" DISPLAY OPTION
Controlling the display of the OK/READY icon based on zone status.
RADIO KEY ARMING, UNSEALED ZONE WARNING
Enabling a siren warning for unsealed zones during radio arming.
24HR ZONE FIRE SIREN SOUND
Changing the siren sound for 24hr zone fire alarms.
SINGLE SHOT STROBE ON ARMING
Enabling single strobe flash on arming by radio key.
QUIET CHIRPS ON ARM/DISARM
Quieting siren chirps for keyswitch or radio key arming/disarming.
PROGRAMMING
FLASH STROBE ON MEDICAL ALARM
Enabling strobe flash for medical alarms.
QUIET HOME SIREN
Selecting a quiet siren sound for Home Mode.
6 BEEPS ON ARMING
Configuring keypad to give 6 beeps on arming.
PROGRAMMING
HOME ARMING BY RADIO KEY ON/OFF BUTTONS
Enabling home mode arming via radio key ON/OFF buttons.
DISABLE MAINS FAIL ALARM
Disabling mains fail alarm display and beeps.
BEEPS DURING EXIT DELAY - FULLY ARMED MODE
Enabling audible warnings during exit delay in fully armed mode.
BEEPS DURING EXIT DELAY - HOME MODE
Enabling audible warnings during exit delay in home mode.
PROGRAMMING
FOLLOW ME TELEPHONE NUMBER
Setting a specific number for audible voice monitoring messages.
TELEPHONE NUMBERS 1 & 2
Programming primary and secondary telephone numbers for calls.
PROGRAMMING
ACCOUNT NUMBER 1 & 2
Setting account numbers for panel identification by the central station.
TELEPHONE NUMBER 3 – TEST CALLS
Programming a number specifically for sending test calls.
TELEPHONE NUMBER 4 – CALLBACK
Programming a number for NessComms callback for remote access.
PROGRAMMING
REPORT ZONE ALARMS
Selecting which zone inputs send Alarm reports to the Central Station.
REPORT ZONE RESTORALS
Selecting which zone inputs send Restoral reports to the Central Station.
REPORT MULTIPLE ZONE ALARMS
Configuring zones to report each time they alarm without a restore.
ACCOUNT NO.2 ZONES
Assigning zones to report Alarms, Restorals, and Excludes on Account No.2.
PROGRAMMING
REPORT MISCELLANEOUS ALARMS
Selecting which miscellaneous alarms trigger dialler reports.
REPORT MISCELLANEOUS RESTORALS
Selecting which miscellaneous alarms trigger dialler restoral reports.
RESTORAL REPORTING OPTIONS
Selecting when the dialler sends zone Restoral reports.
PROGRAMMING
TEST CALL INTERVAL
Setting the interval for sending test calls to the Central Station.
TIME BEFORE NEXT TEST CALL
Setting the preferred time for test calls.
PROGRAMMING
DISABLE DIALLER
Disabling the dialler without affecting other dialler options.
CONTACT ID FORMAT
Enabling Contact ID format for reporting alarms to Central Station.
PROGRAMMING
AUDIBLE VOICE FORMAT
Sending zone alarms in Audible VOICE format for remote phone operation.
CONTACT ID + AUDIBLE VOICE FORMAT
Simultaneous Central Station and Audible Monitoring.
PROGRAMMING
SPLIT DIAL PRIMARY/SECONDARY PHONE NUMBERS
Selecting the order in which telephone numbers 1 & 2 are dialled.
CHECK FOR DIAL TONE
Programming the dialler to check for a dial tone before dialling.
NUMBER OF DIALLING ATTEMPTS
Setting the number of dialling attempts when sending reports.
PSTN - REDUCE TONE LEVELS
Reducing PSTN tone levels for VOIP type phone lines.
PROGRAMMING
SEND AREA 1 OPEN/CLOSE REPORTS
Enabling or disabling sending of AREA1 Open/Close reports.
SEND AREA 2 Open/Close reports
Enabling or disabling sending of AREA2 Open/Close reports.
SIREN CHIRP ON KISS-OFF
Selecting a 2 Second Siren burst on a successful Closing report.
STROBE FLASH ON KISS-OFF
Selecting a 2 Second Strobe on a successful Closing report.
PROGRAMMING
FORCED OPENING REPORT
Sending an opening report with a restoral for alarm reset by valid user.
DELAY CLOSING REPORT
Sending closing reports at the end of Exit Time instead of immediately.
MANUAL EXCLUDE REPORT
Enabling Manual Exclude Reports for zones.
AUTO EXCLUDE REPORT
Reporting zones not sealed on arming as Auto Excluded.
PROGRAMMING
ENABLE TEST CALLS
Enabling the reporting of dialler test calls to the Central station.
MAINS REPORT DELAY
Delaying mains fail reports by one hour to avoid brief power failures.
LISTEN-IN TO DIALLER
Diagnostic feature to hear dialler messages and telephone tones.
PROGRAMMING
SWINGER SHUTDOWN
Limiting the number of calls made by a zone alarm in any one armed period.
LINE FAULT MONITOR
Enabling regular testing of the telephone line.
PROGRAMMING
Enable Remote Access
Allowing remote upload/download and telephone control.
ENABLE "FIRST CALL" MODE
Panel answers incoming calls on the first ring.
REMOTE ARMING
Allowing remote arming of the control panel via telephone.
PROGRAMMING
REMOTE DISARMING
Allowing remote disarming of the control panel via telephone.
REMOTE AUX CONTROL
Enabling remote control of AUX outputs via telephone.
REMOTE STATUS AND ARMING
Enabling remote status viewing and keypad operation via software.
REMOTE EVENT REPORTING
Enabling remote event reporting.
CALLBACK MODE
Enabling methods for computer connection for remote upload/download.
PROGRAMMING
REQUIRED RINGS
Setting the number of rings before an incoming call is answered.
"NO MEMORY WARNING"ZONES
Selecting zones that do not flash the Memory indicator on keypads.
PROGRAMMING
CLEAR RADIO DEVICES
Clears all Radio Devices assigned to zones 1-8 or 1-16.
CLEAR MEMORY
Clears all events in the Alarm memory display.
CLEAR PANEL OPTIONS
Restores panel program options to their factory default values.
CLEAR USER CODES
Clears all User Codes, Keypad Codes, Radio Keys, and Access cards.
PROGRAM THE INSTALLER CODE
Programs the installer code, which can be 3 to 6 digits long.
PROGRAMMING
ENABLE OUTPUT EXPANDER
Enables the optional 106-011 Output Expander.
EXPANDER OUTPUT FORMAT A, B, C
Configures output expander outputs according to tables.
PROGRAMMING
DAY ZONE FOLLOWER
Allows Day zones to appear on Zone Outputs based on active Day zones.
OUTPUT EXCLUDE
Allows manual exclusion to also exclude Expander Zone outputs.
EXPANDER OUTPUT FORMAT C
Configures output expander outputs for single or dual expanders.
USER CODE TOGGLE OR PULSE
Changes User Code 13-15 operations to pulse on Radio Key AUX button.
PROGRAMMING
OUTPUT EXPANDER ZONES
Selects zones that will output when unsealed; output goes off when zone reseals.
OUTPUT EXPANDER ALARM ZONES
Selects zones that will output when the zone is latched into alarm.
LATCHED KEYSWITCH
Enables the use of a latched, two-position keyswitch for arming/disarming.
SIREN CHIRP ON HOME ARMING BY RADIO
Enables siren chirps for arming/disarming Home Mode with a Radio Key.
PROGRAMMING
RADIO AUX BUTTON ARMS HOME MODE
Enables the AUX button on a Radio Key to arm Home Mode.
KEYSWITCH DISARM ONLY
Converts keyswitch operation to only disarm Area or Home mode.
KEYSWITCH ARM ONLY
Converts keyswitch operation to only arm Area or Home mode.
SMART BEEPS
Identifies zones by keypad beeps for Brief Home or Brief Day mode.
ENTRY DELAY EXTENDER
Increases the Entry Delay Time1 by a factor of 10.
AREA2 DISARM BY KEYSWITCH ALLOWED
Allows keyswitch to disarm Area2, not arm it.
PROGRAMMING
AUX1 OUTPUT OPTIONS
Controls the behaviour of the AUX1 output via events and alarms.
ZONE ALARMS TO AUX1
Turns on Aux1 when selected zones go into alarm.
ZONE SUPERVISION ALARMS TO AUX1
Turns on Aux1 when a supervised radio alarm is triggered.
ENABLE AUX1 FOR AUTOTIMER / RADIO KEY PANIC TOGGLES AUX1
Enables AUX1 for AutoTimer and Radio Key/s Panic button toggles.
RADIO KEY PANIC PULSES AUX1
Radio Key/s Panic button pulses the Aux1 output.
DOOR OPEN TOO LONG (DOTL) ALERTS TO AUX1
Enables DOTL zones to turn on Aux1 when DOTL Time expires.
READER OUTPUT TO AUX1
Enables access control reader to pulse Aux1 on valid card presentation.
PROGRAMMING
ENHANCED AUX1 OUTPUT OPTIONS
Provides multiple choices of events and alarms to control AUX1.
AREA 1 ARMED TO AUX1
Turns on AUX1 while Area 1 is armed.
AREA 2 ARMED TO AUX1
Turns on AUX1 while Area 2 is armed.
HOME ARMED TO AUX1
Turns on AUX1 while armed in Home mode.
KEYPAD TOGGLE AUX1
Turns AUX1 ON/OFF or PULSED with keypad keypresses.
TELEPHONE REMOTE CONTROL OF AUX1
Controls AUX1 ON/OFF or PULSED via telephone remote control.
PULSE AUX1
Converts options into a pulsed AUX1 output for a set time.
AUX1 TIMER
Sets the pulse time for the AUX1 output when P141E 8E is selected.
PROGRAMMING
AUX2 OUTPUT OPTIONS
Controls the behaviour of the AUX2 output via events and alarms.
ZONE ALARMS TO AUX2
Turns on Aux2 when selected zones go into alarm.
ZONE SUPERVISION ALARMS TO AUX2
Turns on Aux2 when a supervised radio alarm is triggered.
ENABLE AUX2 FOR AUTOTIMER / RADIO KEY AUX TOGGLES AUX2
Enables AUX2 for AutoTimer and Radio Key/s AUX button toggles.
RADIO KEY AUX BUTTON PULSE AUX2
Radio Key/s AUX button pulses the Aux2 output.
TELEPHONE LINE FAULT TO AUX2
Turns on Aux2 when a telephone line fault condition occurs.
DOOR OPEN TOO LONG (DOTL) ALERTS TO AUX2
Enables DOTL zones to turn on Aux2 when DOTL Time expires.
READER OUTPUT TO AUX2
Enables access control reader to pulse Aux2 on valid card presentation.
PROGRAMMING
ENHANCED AUX2 OUTPUT OPTIONS
Provides multiple choices of events and alarms to control AUX2.
AREA 1 ARMED TO AUX2
Turns on AUX2 while Area 1 is armed.
AREA 2 ARMED TO AUX2
Turns on AUX2 while Area 2 is armed.
HOME ARMED TO AUX2
Turns on AUX2 while armed in Home mode.
KEYPAD TOGGLE AUX2
Turns AUX2 ON/OFF or PULSED with keypad keypresses.
TELEPHONE REMOTE CONTROL OF AUX2
Controls AUX2 ON/OFF or PULSED via telephone remote control.
PULSE AUX2
Converts options into a pulsed AUX2 output for a set time.
AUX2 TIMER
Sets the pulse time for the AUX2 output when P142E 8E is selected.
PROGRAMMING
AUX3 OUTPUT OPTIONS
Controls the behaviour of the AUX3 output via events and alarms.
ZONE ALARMS TO AUX3
Turns on Aux3 when selected zones go into alarm.
ENABLE AUX3 FOR AUTOTIMER
Enables AUX3 for AutoTimer.
RADIO KEY PANIC PULSES AUX3
Radio Key/s Panic button pulses the Aux3 output.
READER OUTPUT TO AUX3
Enables access control reader to pulse Aux3 on valid card presentation.
PROGRAMMING
ENHANCED AUX3 OUTPUT OPTIONS
Provides multiple choices of events and alarms to control AUX3.
AREA 1 ARMED TO AUX3
Turns on AUX3 while Area 1 is armed.
AREA 2 ARMED TO AUX3
Turns on AUX3 while Area 2 is armed.
HOME ARMED TO AUX3
Turns on AUX3 while armed in Home mode.
KEYPAD TOGGLE AUX3
Turns AUX3 ON/OFF or PULSED with keypad keypresses.
TELEPHONE REMOTE CONTROL OF AUX3
Controls AUX3 ON/OFF or PULSED via telephone remote control.
PULSE AUX3
Converts options into a pulsed AUX3 output for a set time.
AUX3 TIMER
Sets the pulse time for the AUX3 output when P143E 8E is selected.
PROGRAMMING
AUX4 OUTPUT OPTIONS
Controls the behaviour of the AUX4 output via events and alarms.
ZONE ALARMS TO AUX4
Turns on Aux4 when selected zones go into alarm.
ENABLE EXTENSION SONALERT
Duplicates keypad beeps including keypress beeps on Aux4.
ENABLE AUX4 FOR AUTOTIMER
Enables AUX4 for AutoTimer.
RADIO KEY PANIC PULSES AUX4
Radio Key/s Panic button pulses the Aux4 output.
ENABLE AUX4 FAIL TO COMMUNICATE OUTPUT
Turns on Aux4 at start of fourth dialout attempt for backup comms.
READER OUTPUT TO AUX4
Enables access control reader to pulse Aux4 on valid card presentation.
PROGRAMMING
ENHANCED AUX4 OUTPUT OPTIONS
Provides multiple choices of events and alarms to control AUX4.
AREA 1 ARMED TO AUX4
Turns on AUX4 while Area 1 is armed.
AREA 2 ARMED TO AUX4
Turns on AUX4 while Area 2 is armed.
HOME ARMED TO AUX4
Turns on AUX4 while armed in Home mode.
KEYPAD TOGGLE AUX4
Turns AUX4 ON/OFF or PULSED with keypad keypresses.
TELEPHONE REMOTE CONTROL OF AUX4
Controls AUX4 ON/OFF or PULSED via telephone remote control.
PULSE AUX4
Converts options into a pulsed AUX4 output for a set time.
AUX4 TIMER
Sets the pulse time for the AUX4 output when P144E 8E is selected.
PROGRAMMING
AUX5, AUX6, AUX7, AUX8 OUTPUT OPTIONS
Options for controlling AUX5, AUX6, AUX7, and AUX8 outputs.
KEYPAD TOGGLE AUX5
Enables keypad control for AUX5 on Output Expanders.
TELEPHONE REMOTE CONTROL OF AUX5
Enables telephone remote control for AUX5 on Output Expanders.
READER OUTPUT TO AUX5
Enables readers to pulse AUX5 upon valid card presentation.
PULSE AUX5
Sets AUX5 to pulse output for keypad operations.
PROGRAMMING
AUX5 - AUX8 TIMERS
Sets the pulse time for AUX5-AUX8 outputs when in Pulse mode.
ALARM SIREN VOLUME
Sets the audible alarm volume level for the siren output.
FIRE SIREN VOLUME
Sets the fire alarm volume level for the siren output.
CHIRP SIREN VOLUME
Sets the chirp volume level for the siren output.
PROGRAMMING
ENABLE HARDWIRED ZONES
Enables or disables hardwired zone inputs, ignoring radio zones.
MISC KEYPAD OPTIONS
Various programming options for KPX, Saturn, and Navigator keypads.
END OF LINE RESISTOR OPTIONS
Programs EOL resistor values for zones and tamper inputs.
AUTOMATION FEATURES
AUTO-TIME FEATURES
Sophisticated automation features using the onboard Real Time Clock.
AutoTimer 1
Configures time, day, and actions for AutoTimer 1.
AutoTimer 2
Configures time, day, and actions for AutoTimer 2.
AutoTimer 3
Configures time, day, and actions for AutoTimer 3.
AutoTimer 4
Configures time, day, and actions for AutoTimer 4.
REALTIME CLOCK PROGRAMMING
AUTOTIME WARNING PERIOD
Enables keypad beep to warn that an AutoTime action is due.
ENABLE AUTOTIME USER CODES
Toggle the current setting for enabling/disabling user codes by AutoTimers.
AUTOTIMER 1 / AutoTimers 2-8
TO ENABLE AUTO-ARMING
Enables auto-arming of Area 1, Area 2, or Home Mode.
TO ENABLE/DISABLE USER CODES BY AUTOTIMER
Enables/disables user codes based on AutoTime schedule.
TO ENABLE PRE-EVENT WARNING BEEPS
Enables keypad beeps to warn about upcoming AutoTime events.
TO ENABLE AUTO-DISARMING FOR EACH AREA
Enables auto-disarming of Area 1, Area 2, or Home Mode.
TO CONTROL OUTPUTS BY AUTOTIMER
Controls AUX outputs based on AutoTimer actions.
RADIO DEVICES OPERATION
NESS RADIO INTERFACE
Optional serial radio receiver required for all radio functions.
RADIO SIGNAL STRENGTH TEST
Test radio signal strength from any Ness radio device.
RADIO DEVICE PROGRAMMING
PROGRAMMING RADIO DEVICES
Assigning radio devices to zones for alarm and zone inputs.
PROGRAMMING SEQUENCE – NO RESTORALS
Programming sequence for radio PIRs, pendants, and smoke detectors.
PROGRAMMING SEQUENCE - WITH RESTORALS
Programming sequence for radio reed switches with restorals.
RADIO CODES
PROGRAMMING RADIO KEYS
Enabling user codes as Radio Codes for arming/disarming via radio keys.
PROGRAMMING
SERIAL OUTPUT OPTIONS
Configuring two-way serial data communications via RS232 port.
ACCESS CONTROL
DEFAULT ALL ACCESS CONTROL OPTIONS
Returns all access control programs to factory default values.
PROGRAMMING ACCESS CARDS
Programming user codes as Reader Codes for access and AUX output control.
ACCESS CONTROL
USE READER ADDRESSES
Setting reader addresses (1, 2, or 3) for multiple readers.
ARM WITH DOUBLE READ
Arming the panel if the same card is presented twice within 5 seconds.
ARM WITH SINGLE READ AND PUSHBUTTON
Arming with a card presentation and zone 8 unsealing momentarily.
DISARM WITH ACCESS CARD
Disarming the panel using a valid access card.
REQUEST TO EXIT (REX) INPUTS
Converting zones to REX inputs for access control, allowing push button door exit.
ACCESS CONTROL
STROBE FLASH ON ARM/DISARM BY READER
Enabling strobe flash when arming/disarming by reader.
DOOR OPEN TOO LONG (DOTL) ZONES
Selecting zones that generate a DOTL alert if unsealed longer than P304E.
DOTL TIME
Setting the delay time in seconds before a DOTL zone generates an alert.
ACCESS CONTROL
DOTL OUTPUT LATCHES
DOTL alerts either follow zone state or latch Aux outputs.
DOTL ALERTS TO OUTPUT EXPANDER
Sending DOTL alerts to the optional Output Expander.
DOTL TIMER IN MINUTES
Changing the P304E timer to minutes for longer DOTL times.
DOTL TIMER IN HOURS
Changing the P304E timer to hours for extra long DOTL times.
DOTL ALERTS TO KEYPAD
Slowly flashing zone lights on the keypad for DOTL alerts.
ACCESS CONTROL
READERS 1-3 to AUX OUTPUTS 1-8
Assigning access readers to any Aux output for door strikes, locks, etc.
ACCESS CONTROL
READERS 1-3 OUTPUT TIME
Setting the time outputs selected by readers are ON.
ACCESS CONTROL
WIRING A SINGLE READER
Connecting a single reader to the panel.
WIRING MULTIPLE READERS
Connecting multiple readers and identifying them via addresses.
REQUEST TO EXIT (REX) USING A KEYPAD CODE
Using Code Only Arming codes as REX codes for access control.
CENTRAL STATION MONITORING
AUDIBLE MONITORING
Operation of Audible Monitoring, including voice messages.
AUDIBLE VOICE MONITORING - ENHANCED
Enhanced features for clear and concise spoken word alarm messages.
ALARM MESSAGE TRANSMISSION
How alarm reports are sent to telephone numbers.
ALARM MESSAGE FORMAT
Structure of the alarm message and interaction with the recipient.
SYSTEM NAME
VOICE MESSAGE LIBRARY
Library of pre-recorded voice messages for alarms and prompts.
TELEPHONE REMOTE CONTROL
HOW TO INITIATE TELEPHONE REMOTE CONTROL
Steps to initiate remote control session via telephone.
OPERATION
How to control system functions like arming, outputs, and zones remotely.
SPECIFICATIONS
INPUTS/OUTPUTS
Details of zones, tamper inputs, and output capabilities.
APPROVALS
Compliance with EMC, Telecom, and Safety standards.

Table of Contents