The configuration below shows the MIDI connections for controlling the PCM 90
simultaneously with MIDI Clocks from a sequencer, and messages from another
MIDI controller. Note that the controller is set to "local control off" and the
sequencer is set to "echo input".
MIDI In
PCM 90 Tempo 0.2 Source set to MIDI
Two PCM 90s can be slaved together by connecting a cable from the MIDI OUT
jack of the master to the MIDI IN jack of the slave. Additional PCM 90s can be
slaved to the master by connecting a cable from the MIDI THRU port of one slave
unit to the MIDI IN port of the next unit. All of the PCM 90s must be set to the same
MIDI channel and Device ID.
MIDI In
Control 3.7 MIDI SysEx set to Receive On
MIDI In
MIDI Thru
MIDI Out
MIDI Out
Control 3.4 Automation set to On
Target ID set to All or same # as Slave device ID #
MIDI Operation
MIDI Out
MIDI In
(MIDI Clock)
Slaving two or more
PCM 90s
5-3