Calibration - Simrad NX40 Installation & Operation Manual

Navstation
Table of Contents

Advertisement

58

13-7 Calibration

Calibrate
installation, or if the fuel readings seem inaccurate and
the other troubleshooting suggestions do not help (see
Appendix B troubleshooting).
Note
SmartCraft fuel sensors are factory calibrated and
should never need recalibrating.
On a multi engine boat, calibrate each engine's
sensor. This can be done at the same time with a
portable tank for each engine or at different times
using one portable tank.
Calibrating
measurement
This is best done using a small portable tank. At
least 4 gallons (15 litres) of fuel should be used to
ensure an accurate calibration.
• It is often very difficult to fill underfloor tanks to the
same level twice due to air pockets, so the more fuel
used, the more accurate the calibration.
To calibrate the sensor(s)
Record the level of the fuel in the tank(s).
Connect the portable tank(s) to the engine through
the fuel sensor(s).
Run the engine at normal cruising speed until at
least 4 gallons (15 litres) of fuel has been used per
engine.
Check the actual amount of fuel used per engine by
refilling the portable tank(s) to the original level and
noting the reading(s) of the fuel dispenser's gauge.
On a single engine boat, select
the shown value to be equal to the reading of the
fuel dispenser's gauge, then press
On a multi-engine boat select the engine. Select
Calibrate
to the reading of the fuel dispenser's gauge, then
press
Simrad NX40/45 Installation and Operation Manual
petrol/gasoline
fuel
a
sensor
of
the
>
>
Fuel
and change the shown value to be equal
. Repeat for the other engines.
flow
sensors
requires
accurate
fuel
consumption.
>
Setup engines
and change
Calibrate
.
during