Download Print this page

enphase IQ Battery 10C Quick Install Manual page 6

Advertisement

photovoltaic system. Disconnect the power coming from
the photovoltaics before servicing or installing.
DANGER: Risk of electric shock. Always de-energize the
AC branch circuit during an emergency and/or before
servicing the IQ Battery(ies).
DANGER: Risk of electric shock. Risk of high short-
circuit current. Observe the following precautions when
working on batteries:
Remove watches, rings, or other metal objects.
Use tools with insulated handles.
Wear insulating gloves and boots.
Do not lay tools or metal parts on top of batteries.
DANGER: Risk of electric shock. Risk of fire. Do not work
alone. Someone should be in the range of your voice or
close enough to come to your aid when you work with or
near electrical equipment.
DANGER: Risk of fire. Do not allow or place flammable,
sparking, or explosive items near the IQ Battery(ies).
DANGER: Risk of electric shock. In areas where flooding
is possible, install the IQ Battery(ies) at a height that
prevents water ingress.
DANGER: Risk of electric shock. AC voltage is present at
the output when the DC switch is on.
DANGER: Risk of electric shock. Branch circuit
protection must be off before switching DC power on
or off.
DANGER: Risk of electric shock. The DC switch must be
in the OFF position for shipping and service.
WARNING: Multiple risks. Follow all local standards
and regulations set forth by the Utility companies and
Authority Having Jurisdiction (AHJ).
WARNING: Risks of electric shock, energy hazard, and
chemical hazard. Do not disassemble.
WARNING: Risk of equipment damage. During use,
storage, transport, or installation, always keep the
IQ Battery(ies) in an upright position.
WARNING: You must install the IQ Battery(ies) only on a
suitable wall using an Enphase mounting bracket.
WARNING: Before installing or using the IQ Battery(ies),
read all instructions and cautionary markings in this
guide and on the equipment.
WARNING: Do not install or use the IQ Battery(ies) if it
has been damaged in any way.
WARNING: Do not exceed the maximum number (1) of
IQ Battery 10C without PCS or maximum number (2) of
IQ Battery 10C with PCS in a 40 A AC branch circuit
WARNING: Do not exceed the maximum number (2) of
IQ Battery 10C without PCS or maximum number (4) of
IQ Battery 10C with PCS on 80 A AC branch circuit.
WARNING: Do not sit on, step on, place objects on, or
insert objects into the IQ Battery(ies).
WARNING: Do not place beverages or liquid containers
on top of the IQ Battery(ies). Do not expose the
IQ Battery(ies) to liquids or flooding.
WARNING: Risk of injury and equipment damage. The
total lifting weight is 125.6 lb (57 kg). Handles (SKU:
B05C-LH-0180-O) must be used while lifting the battery.
Two-person manual lifting is allowed only if permitted by
local laws. Otherwise, use mechanical lifting.
WARNING: Risk of injury and equipment damage.
Do not lift the IQ Battery 10C battery units by holding
onto the microinverters. This may damage the unit
permanently.
Do not lift the packaging with the battery inside after
the plastic straps are cut.
Do not mount an IQ Battery 10C on a bracket that is
not properly mounted.
WARNING: Multiple risks. While drilling, make sure not to
drill into electric wiring or water pipes in the wall.
WARNING: Risk of equipment damage. Use an electric
drive; do not use impact drives/impact drills while
tightening fasteners provided along with the product.
Ensure that fasteners are torqued to the recommended
limits.
WARNING: Risk of injury. Wear personal protective
equipment for handling lithium batteries as required by
local safety standards during installation and handling of
IQ Battery.
WARNING: Limitation of use. Your IQ Battery 10C
unit is not intended for use as a primary or backup
power source for life-support systems, other medical
equipment, or any other use where product failure could
lead to injury, loss of life, or catastrophic property
damage. Enphase disclaims any and all liability arising
out of any such use of your IQ Battery 10C unit. Further,
Enphase reserves the right to refuse to provide support
in connection with any such use and disclaims any and
all liability arising out of Enphase's provision of, or refusal
to provide support for your IQ Battery 10C device in
such circumstances.
WARNING: When placing the IQ Battery(ies) in storage,
ensure that AC power is not present and that the
DC switch is in the OFF state (LED not on). While in
storage, damage to the battery can occur from over-
discharge. If the battery state of charge falls to 0%, the
IQ Battery(ies) can be damaged or destroyed. Because
of this, the IQ Battery(ies) must only be stored for a
limited amount of time.
The IQ Battery(ies) must be installed and energized
by the "Must Energize By" date on the shipping box
label.
The IQ Battery(ies) must have a SoC (State of
Charge) of no more than 30% when placed in
storage. To do this, the IQ Battery(ies) must be
switched OFF when it reaches 30% SoC.
If the IQ Battery(ies) has already been installed, it
must be discharged to 30% SoC and be switched
OFF prior to uninstalling. A battery in OFF state can
be stored for a maximum of two months from the
time it was switched OFF.
NOTE: Inspect the packaging and the IQ Battery(ies)
for any signs of damage, such as cracks, dents, or
electrolyte leaks. Do not install or use the IQ Battery(ies)
if it has been dropped or damaged in any way. If it is
damaged, contact your distributor for replacement.
NOTE: These mounting instructions are for the
included mounting bracket only. If you wish to install
IQ Battery 10C in a floor-mount configuration, order
the pedestal accessory (B05C-PI-0550-O) and refer to
the floor-mount instructions shipped with the product.
This product must be installed with clearance at the
left, right, top, bottom, and front, as shown in section
– minimum clearances.
EN-6