Generac Power Systems GP Series Owner's Manual page 21

Multi-fuel portable generator
Hide thumbs Also See for GP Series:

Advertisement

Available languages

Available languages

Figure 3-3.Gas/LP Dial
5. See
Figure
2-2. Turn engine STOP/RUN/
START switch to RUN (manual start only).
6. See
Figure
3-4. Slide engine choke (C) to
Full Choke position (left).
C
Figure 3-4.Choke Position
7. Brace one hand against the frame and
firmly grasp recoil handle. Pull slowly until
increased resistance is felt, then pull rap-
idly up and away.
8. When engine starts, move choke lever to
1/2-choke position until engine runs
smoothly, then fully into RUN position. If
engine falters, move choke back to 1/2-
choke position until engine runs smoothly,
then to RUN position.
NOTE: If engine fires, but does not continue to
run, move choke lever to Full Choke and
repeat starting instructions.
IMPORTANT NOTE: Do not overload the
generator. Also, do not overload individual
panel receptacles. These outlets are pro-
tected against overload with push-to-reset-
type circuit breakers. If amperage rating of
any circuit breaker is exceeded, that
breaker opens and electrical output to that
receptacle is lost. Read
Limits
carefully.
Owner's Manual for Portable Generator
020086
000209
Know Generator
Starting Gasoline Electric Start
Engines - 50 State Models
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. Turn engine GAS/LP dial to GAS.
4. Press and hold RUN/STOP/START switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
Starting Gasoline Electric Start
Engines - 49 State Models
Equipment and property damage. Disconnect
electrical loads prior to starting or stopping unit.
Failure to do so could result in equipment and
property damage.
1. Unplug all electrical loads from the unit's
receptacles before starting the engine.
2. Place generator on a level surface.
3. See
Figure
3-2. Open the fuel shut-off
valve.
4. Turn engine GAS/LP dial to GAS.
5. See
Figure
3-4. Move engine choke lever
outward to Full Choke.
6. Press and hold STOP/RUN/START switch
in the START position. When engine
starts, release the switch to the RUN posi-
tion.
7. When engine starts, move choke lever to
1/2 choke position until engine runs
smoothly, then fully to RUN position. If
engine falters, move choke lever back to
1/2 choke position until engine runs
smoothly, then move to RUN position.
Starting LP Pull Start Engines -
49 and 50 State Models
NOTE: Follow the start-up guide decal to pre-
start the unit.
NOTE: 49 and 50 State models can only pull
start on LP with a battery connected.
1. Unplug all electrical loads from the unit's
receptacles before starting engine.
2. Place generator on a level surface.
3. See
Figure
3-5. Open fuel shut-off valve on
cylinder.
4. Turn GAS/LP dial to LP. For 49 State Mod-
els, move engine choke lever to the RUN
position (choke lever to the right).
CAUTION
CAUTION
(000136)
(000136)
19