3-16 Compaq ProLiant ML330e/ML330 Server Setup and Installation Guide
4. Slide the device into the drive bay
each side of the device
Figure 3-16. Installing a device into a 5.25-inch drive bay.
5. Connect the data and power cables to the back of the device, as shown
in Figure 3-14.
6. Replace the access panel and the front bezel. Restore power to
the server.
To install a tape drive:
CAUTION: To prevent damage to equipment or loss of information, make sure
that the server is powered down, all cables are disconnected from the back of
the server, and the power cord is disconnected from the grounded (earthed) AC
outlet before removing the access panel.
IMPORTANT: When installing a removable media device, remove the rails included in the
drive tray and install them on the device (replace any existing rails on the device). The
rails are secured to the drive tray with two screws on each rail.
1. Follow the steps in "Removing the Access Panel" and "Removing the
Bezel Blanks" at the beginning of this chapter.
2. Set the SCSI ID on the drive. You must manually set the SCSI ID on
each device to a unique value in the range of 0 to 6 for each SCSI bus.
Refer to the documentation provided with the device for instructions on
how to set the SCSI ID.
, and then secure with screws on

as shown in Figure 3-16.