Dell PowerEdge E07S Series Owner's Manual page 43

Dell server hardware owner's manual
Table of Contents

Advertisement

Table 1-3. System Messages (continued)
Message
Memory set to
minimum
frequency.
Memory tests
terminated by
keystroke.
MEMTEST lane
failure detected
on x.
No boot device
available.
Causes
The memory frequency may
be intentionally set lower for
power conservation.
The current memory
configuration may support
only the minimum frequency.
POST memory test was
terminated by pressing the
spacebar.
Invalid memory
configuration. Mismatched
memory modules are
installed.
Faulty or missing optical
drive subsystem, hard drive,
or hard drive subsystem, or
no bootable USB key
installed.
Corrective Actions
If not an intentional setting,
check any other system
messages for possible causes.
Ensure that your memory
configuration supports the
higher frequency.
See "General Memory
Module Installation
Guidelines" on page 106.
Information only.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 106.
Use a bootable USB key,
optical drive, or hard drive.
If the problem persists,
see "Troubleshooting an
Optical Drive" on page 156,
"Troubleshooting a USB
Device" on page 146,
"Troubleshooting an Internal
USB Key" on page 155, and
"Troubleshooting a Hard
Drive" on page 158.
See "Using the System Setup
Program and UEFI Boot
Manager" on page 53 for
information on setting the
order of boot devices.
About Your System
43

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e07s002Poweredge r310

Table of Contents