Dell PowerEdge E07S Series Owner's Manual page 36

Dell server hardware owner's manual
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E2111
SBE log
disabled on
DIMM ##.
Reseat DIMM.
I1910
Intrusion
detected.
Check chassis
cover.
I1911
LCD Log Full.
Check SEL to
review all
Errors.
I1912
SEL full.
Review & clear
log.
I1920
iDRAC6 Upgrade
Successful.
W1228
RAID
Controller
battery
capacity <
24hr.
36
About Your System
Causes
The system BIOS has
disabled memory
single-bit error (SBE)
logging and will not log
anymore SBEs until the
system is rebooted. "##"
represents the memory
module implicated by
the BIOS.
System cover has been
removed.
LCD overflow message.
A maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
The SEL is full of events
and is unable to log any
more.
optional iDRAC6 has
been upgraded
successfully.
Warns predictively that
the RAID battery has
less than 24 hours of
charge left.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 153.
Information only.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
Check the SEL for details
on the events, then clear
the SEL.
Information only.
Allow RAID battery to
charge to greater than
24 hours of
sustained charge.
If problem persists,
replace RAID battery.
See "Getting Help" on
page 169.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge e07s002Poweredge r310

Table of Contents