Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E201D
Shutdown test
failure. Power
cycle AC.
E201E
POST memory
test failure.
Check DIMMs.
E2020
CPU
configuration
failure. Check
screen
message.
E2021
Incorrect
memory
configuration.
Review User
Guide.
E2022
General
failure
during POST.
Check screen
message.
E2110
Multibit Error
on DIMM ##.
Reseat DIMM.
Causes
BIOS shutdown test
failure.
BIOS POST memory test
failure.
Processor configuration
failure.
Incorrect memory
configuration.
General failure after video. Check screen for specific
The memory module in
slot "##" has had a
multi-bit error (MBE).
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
See "Troubleshooting
System Memory" on
page 153.
If the problem persists,
see "Getting Help" on
page 169.
Check screen for specific
error messages.
See "Troubleshooting the
Processor" on page 160.
Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 153.
error messages.
See "Troubleshooting
System Memory" on
page 153.
About Your System