Dell PowerEdge E07S Series Owner's Manual page 27

Dell server hardware owner's manual
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E122A
CPU # VTT
Regulator
failure.
Reseat CPU.
E122C
CPU Power
Fault. Power
cycle AC.
E122D
Memory
Regulator #
Failed. Reseat
DIMMs.
E122E
On-board
regulator
failed. Call
support.
E1310
Fan ## RPM
exceeding
range. Check
fan.
E1311
Fan module ##
RPM exceeding
range. Check
fan.
E1313
Fan redundancy
lost. Check
fans.
Causes
Specified processor VTT
voltage regulator has
failed.
A power fault was
detected when powering
up the processor.
One of the memory
regulators has failed.
One of the on-board
voltage regulators failed.
RPM of specified fan is
outside of the intended
operating range.
RPM of specified fan in
specified module is
outside of intended
operating range.
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.
Corrective Actions
Reseat the processor. See
"Troubleshooting the
Processor" on page 160.
If the problem persists,
see "Getting Help" on
page 169.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 153.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
See "Troubleshooting
System Cooling
Problems" on page 151.
See "Troubleshooting
System Cooling
Problems" on page 151.
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 152.
About Your System