Table 1-3. System Messages (continued)
Message
Unable to launch
System Services
image. System
halted!
Unexpected
interrupt in
protected mode.
Unsupported CPU
combination.
Unsupported CPU
stepping
detected.
Unsupported DIMM
detected. The
following DIMM
has been
disabled: x.
48
About Your System
Causes
System halted after F10
keystroke because System
Services image is either
corrupted in the system
firmware or has been lost due
to system board replacement.
The optional iDRAC6
Enterprise card flash memory
or BMC SPI flash may be
corrupted.
Improperly seated memory
modules or faulty
keyboard/mouse
controller chip.
Processor is not supported by
the system.
Invalid memory
configuration. The system
will run but with the
specified memory module
disabled.
Corrective Actions
Restart the system and
update the Unified Server
Configurator repository to
the latest software to restore
full functionality. See the
Unified Server
Configuration user
documentation for
more information.
Restore the flash memory
using the latest version on
support.dell.com. See the
iDRAC 6 User Guide for
instructions on performing a
field replacement of the
flash memory.
Reseat the memory modules.
See "Troubleshooting
System Memory" on
page 153. If the problem
persists, see "Getting Help"
on page 169.
Install a supported processor.
See "Processor" on page 120.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 106.