Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E2012
Memory
configured but
unusable.
Check DIMMs.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
E2014
CMOS RAM
failure. Power
cycle AC.
E2015
DMA Controller
failure. Power
cycle AC.
E2016
Interrupt
Controller
failure. Power
cycle AC.
E2017
Timer refresh
failure. Power
cycle AC.
Causes
Memory configured, but is
unusable.
The system BIOS failed to
copy its flash image into
memory.
CMOS failure. CMOS
RAM not functioning
properly.
DMA controller failure.
Interrupt controller
failure.
Timer refresh failure.
Corrective Actions
See "Troubleshooting
System Memory" on
page 153.
See "Troubleshooting
System Memory" on
page 153.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.