Download Print this page

ADF Web HD67154-B2 User Manual

Ethernet / devicenet master - converter
Hide thumbs Also See for HD67154-B2:

Advertisement

Quick Links

Industrial Electronic Devices
User Manual
Revision 1.100
English
Ethernet / DeviceNet Master - Converter
(Order Code: HD67154-A1, HD67154-B2, HD67154-A3, HD67154-A4)
For Website information:
www.adfweb.com?Product=HD67154
For Price information:
www.adfweb.com?Price=HD67154-A1
www.adfweb.com?Price=HD67154-B2
www.adfweb.com?Price=HD67154-A3
www.adfweb.com?Price=HD67154-A4
Benefits and Main Features:
Triple electrical isolation
Temperature range: -40°C/+85°C (-40°F/+185°F)
User Manual
ADFweb.com S.r.l.
User Manual Ethernet / DeviceNet Master
Document code: MN67154_ENG
Revision 1.100
For other DeviceNet products see also the following link:
DeviceNet Slave from/to
www.adfweb.com?Product=HD67043
www.adfweb.com?Product=HD67058
www.adfweb.com?Product=HD67134
www.adfweb.com?Product=HD67136
www.adfweb.com?Product=HD67137
www.adfweb.com?Product=HD67138
www.adfweb.com?Product=HD67139
www.adfweb.com?Product=HD67140
www.adfweb.com?Product=HD67141
www.adfweb.com?Product=HD67235
www.adfweb.com?Product=HD67554
DeviceNet Master from/to
www.adfweb.com?Product=HD67151
www.adfweb.com?Product=HD67152
www.adfweb.com?Product=HD67153
www.adfweb.com?Product=HD67555
Do you have an your customer protocol? See the following link:
www.adfweb.com?Product=HD67003
Do you need to choose a device? do you want help?
Ask it to the following link:
www.adfweb.com?Cmd=helpme
Page 1 of 33
(Ethernet)
(M-Bus)
(CANopen SDO Client)
(CANopen SDO Server)
(J1939)
(Modbus Slave)
(Modbus TCP Client)
(Modbus TCP Server)
(Modbus Master)
(CAN)
(PROFIBUS)
(Modbus Slave)
(Modbus TCP Server)
(CANopen)
(PROFIBUS)

Advertisement

loading
Need help?

Need help?

Do you have a question about the HD67154-B2 and is the answer not in the manual?

Questions and answers

Summary of Contents for ADF Web HD67154-B2

  • Page 1 Page 1 of 33 Industrial Electronic Devices User Manual Revision 1.100 English Ethernet / DeviceNet Master - Converter (Order Code: HD67154-A1, HD67154-B2, HD67154-A3, HD67154-A4) For Website information: www.adfweb.com?Product=HD67154 For Price information: www.adfweb.com?Price=HD67154-A1 For other DeviceNet products see also the following link: www.adfweb.com?Price=HD67154-B2...
  • Page 2 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 2 of 33 Industrial Electronic Devices INDEX: UPDATED DOCUMENTATION: Dear customer, we thank you for your attention and we remind you Page that you need to check that the following document is: INDEX Updated UPDATED DOCUMENTATION...
  • Page 3 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 3 of 33 Industrial Electronic Devices SECURITY ALERT: ENERAL NFORMATION To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device, legal and safety regulation are required for each individual application.
  • Page 4 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 4 of 33 Industrial Electronic Devices CONNECTION SCHEME: Figure 1a: Connection scheme for HD67154-A1 ADFweb.com S.r.l.
  • Page 5 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 5 of 33 Industrial Electronic Devices Figure 1b: Connection scheme for HD67154-B2 ADFweb.com S.r.l.
  • Page 6 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 6 of 33 Industrial Electronic Devices Figure 1c: Connection scheme for HD67154-A3 ADFweb.com S.r.l.
  • Page 7 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 7 of 33 Industrial Electronic Devices Figure 1d: Connection scheme for HD67154-A4 ADFweb.com S.r.l.
  • Page 8 Page 8 of 33 Industrial Electronic Devices CHARACTERISTICS: The HD67154-A1, HD67154-B2, HD67154-A3 and HD67154-A4 are converters from Ethernet to DeviceNet Master and vice-versa. They have the following characteristics: Up to 63 DeviceNet slaves devices; Triple isolation between Ethernet - Power Supply, Ethernet - DeviceNet, Power Supply - DeviceNet.
  • Page 9 The devices can be powered at 8…24V AC and 12…35V DC. For more details see the two tables below. Vmin Vmax Vmin Vmax Consumption at 24V DC: Device Consumption [W/VA] HD67154-A1 HD67154-B2 HD67154-A3 HD67154-A4 Caution: Not reverse the polarity power HD67154-A1 HD67154-B2 ADFweb.com S.r.l.
  • Page 10 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 10 of 33 Industrial Electronic Devices HD67154-A3 HD67154-A4 ADFweb.com S.r.l.
  • Page 11 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 11 of 33 Industrial Electronic Devices FUNCTION MODES: The device has got two functions mode depending of the position of the ‘Dip1 of Dip-Switch A’: The first, with ‘Dip1 of Dip-Switch A’ at “OFF” position, is used for the normal working of the device. The second, with ‘Dip1 of Dip-Switch A’...
  • Page 12 Page 12 of 33 Industrial Electronic Devices LEDS (for HD67154-A1/B2): The device has got four (five for HD67154-B2) LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode...
  • Page 13 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 13 of 33 Industrial Electronic Devices LEDS (for HD67154-A3/A4): The device has got four LEDs that are used to give information about the functioning status. The various meanings of the LEDs are described in the table below. Normal Mode Boot Mode ON: At least one slave is not communicating with the...
  • Page 14 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 14 of 33 Industrial Electronic Devices DEVICENET: To terminate the DeviceNet line with a 120Ω resistor it is necessary that the Dip1 of ‘Dip-Switch B’ is at ON position. Cable characteristics: DC parameter: Impedance...
  • Page 15 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 15 of 33 Industrial Electronic Devices ETHERNET: The Ethernet connection must be made using Connector5 of HD67154-A1/B2 or HD67154-A3/A4 with at least a Category 5E cable. The maximum length of the cable should not exceed 100m. The cable has to conform to the T568 norms relative to connections in cat.5 up to 100 Mbps.
  • Page 16 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 16 of 33 Industrial Electronic Devices USE OF COMPOSITOR SW67154: To configure the Converter, use the available software that runs with Windows called SW67154. It is downloadable on the site www.adfweb.com and its operation is described in this document.
  • Page 17 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 17 of 33 Industrial Electronic Devices NEW CONFIGURATION / OPEN CONFIGURATION: “New Configuration” button creates the folder which contains the entire device’s configuration. A device’s configuration can also be imported or exported: To clone the configurations of a programmable “Ethernet / DeviceNet Master - Converter”...
  • Page 18 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 18 of 33 Industrial Electronic Devices SOFTWARE OPTIONS: By pressing the “Settings” ( ) button there is the possibility to change the language of the software and check the updatings for the compositor.
  • Page 19 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 19 of 33 Industrial Electronic Devices In the section “Software Settings”, it is possible to enable/disable some keyboard’s commands for an easier navigation inside the tables contained in the different sections of the software.
  • Page 20 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 20 of 33 Industrial Electronic Devices SET COMMUNICATION: This section defines the fundamental communication parameters of two buses Ethernet and DeviceNet. By pressing the “Set Communication” button from the main window for SW67154 (Fig. 2), the “Set Communication”...
  • Page 21 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 21 of 33 Industrial Electronic Devices DEVICENET NETWORK: By pressing the “DeviceNet Network” button from the main window for SW67154 (Fig. 2), the window “DeviceNet Network” appears (Fig. Here it is possible to define the slaves DeviceNet Devices with their ID, number of Input and number of Output bytes.
  • Page 22 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 22 of 33 Industrial Electronic Devices UPDATE DEVICE: By pressing the “Update Device” button, it is possible to load the created Configuration into the device; and also the Firmware, if necessary. This by using the Ethernet port.
  • Page 23 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 23 of 33 Industrial Electronic Devices Note: When you receive the device, for the first time, you also have to update the Firmware in the HD67154 device. Warning: If Fig.
  • Page 24 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 24 of 33 Industrial Electronic Devices ETHERNET PROTOCOL: This protocol has got two functions for write and read frames. These routines can use both the UDP protocol and the TCP. UNCTION The request include the following byte: Byte Number...
  • Page 25 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 25 of 33 Industrial Electronic Devices RITE UNCTION The request include the following byte: Byte Number Description Type of Operation (Write = 2) ID of the Slave DeviceNet to Write Starting Address Hi Starting Address Lo Number of Byte to Write Hi...
  • Page 26 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 26 of 33 Industrial Electronic Devices IAGNOSTIC With this command is possible to see if all the nodes defined in the “DeviceNet Network” table are in communication with the Converter The request include the following byte: Byte Number Description...
  • Page 27 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 27 of 33 Industrial Electronic Devices MECHANICAL DIMENSIONS: Figure 7a: Mechanical dimensions scheme for HD67154-A1 ADFweb.com S.r.l.
  • Page 28 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 28 of 33 Industrial Electronic Devices Figure 7b: Mechanical dimensions scheme for HD67154-B2 ADFweb.com S.r.l.
  • Page 29 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 29 of 33 Industrial Electronic Devices Figure 7c: Mechanical dimensions scheme for HD67154-A3 ADFweb.com S.r.l.
  • Page 30 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 30 of 33 Industrial Electronic Devices Figure 7d: Mechanical dimensions scheme for HD67154-A4 ADFweb.com S.r.l.
  • Page 31 HD67154: Ethernet / DeviceNet Master - Converter Order Code: HD67154-A1 Ethernet / DeviceNet Master - Converter ( Housing type: A, Terminal Blocks Connectors ) Order Code: HD67154-B2 Ethernet / DeviceNet Master - Converter ( Housing type: B, Terminal Blocks Connectors ) Order Code: HD67154-A3...
  • Page 32 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 32 of 33 Industrial Electronic Devices DISCLAIMER: All technical content within this document can be modified without notice. The content of the document is a under continual renewal. For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal conditions repairs are charged to the user.
  • Page 33 User Manual Ethernet / DeviceNet Master Document code: MN67154_ENG Revision 1.100 Page 33 of 33 Industrial Electronic Devices WARRANTIES AND TECHNICAL SUPPORT: For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com. Otherwise contact us at the address support@adfweb.com RETURN POLICY: If while using your product you have any problem and you wish to exchange or repair it, please do the following: Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com.

This manual is also suitable for:

Hd67154-a1Hd67154-a3Hd67154-a4