Altronix Trove AMAG kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-
assemblies. Kits accommodate up to three (3) AMAG M4000 modules for up to twelve (12) doors in a single enclosure.
Altronix
Model
Number
T2AGK3F8V
5A/250V
T2AGK3F8DV
T2AGK7F8SV
6.3A/250V
T2AGK7F8SDV
T2AGK7F12V
6.3A/250V
T2AGK7F12DV
T2AGK7F12SV
6.3A/250V
T2AGK7F12SDV
eFlow104NBV
T2AGK75F12V
6.3A/250V
eFlow102NBV
T2AGK75F12DV
5A/250V
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1.
Remove backplane from enclosure. Do not discard hardware.
2.
Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the
screw heads protruding. Place the enclosure's upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes.
Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's upper
keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3.
Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite
hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2" from the right side
(Fig. 1, pg. 2). Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4.
Mount AMAG M4000 modules to TAM2 backplane, refer to page 3-7.
5.
Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NBV, eFlow102NBV,
eFlow104NBV, and corresponding Sub-Assembly Installation Guides for the following models:
ACM4(CB), ACM8(CB), ACMS8(CB), PD4UL(CB), PDS8(CB) and VR6 for further installation instructions.
Hardware:
Nylon Spacer |
- 2 -
Configuration Chart:
Maximum
Output Voltage
Supply
Current for
Main
and Aux.
Outputs
on Power
Supply
board and
Access
Power
Output
Controllers'
Range
outputs
15A/
24VDC @
20.17-
2.5
32V
5.4A
15A/
24VDC @
20.17-
2.7
32V
9.4A
15A/
24VDC @
20.17-
2.7
32V
9.4A
15A/
24VDC @
20.17-
2.7
32V
9.4A
24VDC @
20.17-
9.4A
15A/
4.8
32V
12VDC @
10A
Installation Instructions:
5/16" Pan Head Screw |
Overview:
Nominal DC
[DC]
[Aux]
Output
Range
(VDC)
(VDC)
–
20.28-
8
8
26.4
26.4
–
–
20.28-
8
8
26.4
26.4
–
10A/
32V
20.28-
12
8
26.4
26.4
9A
10A/
32V
20.28-
12
8
26.4
26.4
9A
20.28-
10A/
26.4
26.4
32V
12
4
9.7-
10.03-
9A
13.2
13.2
Lock Nut
10A/
3.5A/
–
–
250V
250V
10A/
–
2.5A
–
250V
15A/
–
–
–
32V
–
–
–
9A
3A/
10A/
3.5A/
–
32V
250V
250V
10A/
2.5A
2.5A
–
250V
3A/
15A/
–
–
32V
32V
2.5A
–
–
9A
3A/
10A/
3.5A/
–
32V
250V
250V
10A/
2.5A
2.5A
–
250V
Edge of
Enclosure
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Trove AMAG M4000 Kits Installation Guide
10A/
3A/
–
–
32V
32V
–
9A
9A
–
3A/
10A/
3A/
–
32V
32V
32V
9A
9A
9A
–
10A/
3A/
–
–
32V
32V
–
9A
9A
–
3A/
10A/
3A/
–
32V
32V
32V
9A
9A
9A
–
3.5A/
–
–
–
250V
–
–
–
2.5A
Fig. 1
Enclosure