Access & Power Integration
Altronix/Lenel-S2 (S2 Security Platform) Kits
Models Include:
T2SSK7F8
8 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with
TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8 - Fused Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input Fused Power Distribution Module
- One (1) RSB1* - Rocker Switch Bracket with
One (1) Rocker Switch (Not evaluated by UL)
T2SSK75F14
14 Door Kit with Fused Outputs
Fully assembled kit includes:
- Trove2 enclosure with
TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8 - Fused Access Power Controllers
- Two (2) PD8UL - Fused Power Distribution Module
- One (1) RSB2* - Rocker Switch Bracket with
Two (2) Rocker Switches (Not evaluated by UL)
All components of this Trove kit are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
Installation Guide
All registered trademarks are property of their respective owners.
Rev. TSSK2_051520
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
T2SSK7F8D
8 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with
TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) ACM8CB - PTC Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
- One (1) RSB1* - Rocker Switch Bracket with
One (1) Rocker Switch (Not evaluated by UL)
T2SSK75F14D
14 Door Kit with PTC Outputs
Fully assembled kit includes:
- Trove2 enclosure with
TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane
- One (1) eFlow104NB - Power Supply/Charger
- One (1) eFlow102NB - Power Supply/Charger
- Two (2) ACM8CB - PTC Access Power Controllers
- Two (2) PD8ULCB - PTC Power Distribution Module
- One (1) RSB2* - Rocker Switch Bracket with
Two (2) Rocker Switches (Not evaluated by UL)
More than just power.™

Advertisement

loading
Need help?

Need help?

Do you have a question about the TROVE T2SSK7F8D and is the answer not in the manual?

Questions and answers

Summary of Contents for Altronix TROVE T2SSK7F8D

  • Page 1 Fully assembled kit includes: Fully assembled kit includes: - Trove2 enclosure with - Trove2 enclosure with TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane TSS2 Altronix/Lenel-S2 (S2 Security Platform) backplane - One (1) eFlow104NB - Power Supply/Charger - One (1) eFlow104NB - Power Supply/Charger...
  • Page 2: Configuration Chart

    Overview: Altronix T2SSK7F8 and T2SSK75F14 Trove S2 kits are pre-assembled and consist of Trove enclosures/backplanes with factory installed Altronix power supply/chargers and sub-assemblies. Both kits accommodate Lenel-S2 (S2 Security Platform) S2-INST Installation Kit for S2 Network Node for up to eight (8) (T2SSK7F8(D)) or fourteen (14) (T2SSK75F14(D)) doors in a single enclosure.
  • Page 3 OUT4 OUT5 OUT6 OUT7 OUT8 Common (--- ) Common (--- ) DM2 + DM2 + Common Power Outputs (NEG) Altronix VR6 is mounted under PDS8(CB) Fig. 2a Lock nut Backplane S2-INST Bracket Trove2 S2 Kits Installation Guide - 3 -...
  • Page 4 INPUT IN GND IN GND IN GND IN GND IN GND IN GND IN GND IN GND Altronix - ACM8(CB) MAIN 10A 250V NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM NC C NO COM...
  • Page 5 Notes: Trove2 S2 Kits Installation Guide - 5 -...
  • Page 6 Notes: - 6 - Trove2 S2 Kits Installation Guide...
  • Page 7 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
  • Page 8 5.25” (133.4mm) Altronix is not responsible for any typographical errors. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty IITrove SS Kits I23U MEMBER - 8 -...

This manual is also suitable for:

Trove t2ssk7f8Trove t2ssk75f14Trove t2ssk75f14d