AEU-1000BSB-70V
Dental Implant Motor System
(AHP-85MB-X)*
*Shown with optional equipment purchased separately
OPERATION AND
MAINTENANCE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEU-1000BSB-70V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aseptico AEU-1000BSB-70V

  • Page 1 AEU-1000BSB-70V Dental Implant Motor System (AHP-85MB-X)* *Shown with optional equipment purchased separately OPERATION AND MAINTENANCE MANUAL...
  • Page 2: Safety Precautions

    AEU-1000BSB-70V ! SAFETY PRECAUTIONS Blue Sky Bio, LLC accepts no liability for direct or consequential injury or s WARNING: Do not use this device in conjunction with an electric scalpel or on patients with pacemakers. damage resulting from improper use, arising in particular through the...
  • Page 3: Table Of Contents

    INTENDED PURPROSE & INTENDED USERS . . . . . . . . . . . . .3 Your new Blue Sky Bio AEU-1000BSB-70V system is one of the finest and most affordable dental implant motor systems available to the PACKAGE CONTENTS .
  • Page 4: Package Contents

    AEU-1000BSB-70V PACKAGE CONTENTS AE-70V2BSB Foot Controller Power Cord Console Cradle Irrigation Tubing Set Motor and Cord Spare Peristaltic Tubes Bag Hanger...
  • Page 5: Purchased Separately

    AEU-1000BSB-70V SYSTEM SETUP Connect the foot controller plug  to the socket on the back of the console. This section provides step-by-step instructions for setting up the unit.  The foot controller plug is “keyed” to the socket and can only be inserted in one position, with the notch ...
  • Page 6 AEU-1000BSB-70V SYSTEM SETUP (Continued) 10 . Two red arrows on the pump door show the direction to install the irrigation tubing. Start by threading the peristaltic tube segment through the top slot in the pump door. The Place the motor-handpiece onto the cradle ...
  • Page 7 AEU-1000BSB-70V 13 . With one hand, pull the irrigation tube firmly from the bottom 16 . Press the power switch on the rear of the console to the of the pump door . Use the other hand to guide the irriga- on (I) position to turn the unit on.
  • Page 8: Control Panel

    AEU-1000BSB-70V • RATIO SETTING: Press the number that appears between the CONTROL PANEL  and  buttons to select the ratio setting: This section describes the functions of the touch-screen. NUMBER DISPLAYED HANDPIECE RATIO SETTING 20:1 Home Screen Press anywhere on the right side of the screen to return to the home screen.
  • Page 9: Customizing Presets

    AEU-1000BSB-70V Customizing Presets If calibration is successful, the CAL button will stop flashing when the motor stops. The Preset segment of the screen will flash if you have made  If the CAL button continues to flash after the motor stops, any manual adjustments to the settings of the current preset: calibration has failed.
  • Page 10: Operation

    AEU-1000BSB-70V OPERATION MAINTENANCE AND STERILIZATION This section explains how to operate the unit using the foot controller. Failure to adhere to the following instructions or blatant misuse of the device and/or related components will be considered abuse of the device and will void the warranty.
  • Page 11 AEU-1000BSB-70V STERILIZATION STERILIZATION METHODS: Wrapped Sterilization — Place in an appropriately sized steriliza- Inspection tion pouch and seal. While precleaning, inspect the motor, cable, and irrigation Standard autoclaving (Gravity displacement method) tubing for damage or material degradation. Do not use the device if it appears damaged or defective.
  • Page 12: Messages

    Dispose of the • Make sure the irrigation tubing is properly installed in pump AEU-1000BSB-70V and accessories at the end-of-life in accordance door and flow is in the correct direction. with your local, state and country laws.
  • Page 13: Fuse Replacement

    AEU-1000BSB-70V FUSE REPLACEMENT SPECIFICATIONS CONSOLE DIMENSIONS: 19.6 cm W x 18.0 cm D x 16.0 cm H (7.72” W x 7.09” D x 6.30” H) WARNING CONSOLE WEIGHT: 1.41 kg (3.11 lbs) Switch off the power and unplug the unit POWER SOURCE: 100-240V, 50-60Hz before following the steps below.
  • Page 14: Symbol Descriptions

    AEU-1000BSB-70V SYMBOL DESCRIPTIONS Model Number Consult Instructions For Use Country of manufacture, USA Type B Equipment Medical Device Caution Rx Dental Use Only Dental Use Only Alternating Current Authorized European Representative Fuse Rating Authorized United Kingdom Representative Dangerous Voltage Motor Direction...
  • Page 15: Custom Presets

    AEU-1000BSB-70V CUSTOM PRESETS Use the blank tables below to write down your custom preset settings: PRESET DIRECTION SPEED RATIO TORQUE WATER PRST-1 PRST-2 PRST-3 PRST-4 PRST-5 PRST-6 PRST-7 PRST-8 PRESET DIRECTION SPEED RATIO TORQUE WATER PRST-1 PRST-2 PRST-3 PRST-4 PRST-5...
  • Page 16 blueskybio.com P/N 421155 • Rev. F • ECO TBD • 01/2025 • Printed in the USA...