Aseptico AEU-7P Operation And Maintenance Instruction Manual

Aseptico AEU-7P Operation And Maintenance Instruction Manual

Peristaltic water pump

Advertisement

Quick Links

OPERATION and MAINTENANCE
INSTRUCTION MANUAL
AEU-7/AEU-7P Peristaltic Water Pump

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEU-7P and is the answer not in the manual?

Questions and answers

Summary of Contents for Aseptico AEU-7P

  • Page 1 OPERATION and MAINTENANCE INSTRUCTION MANUAL AEU-7/AEU-7P Peristaltic Water Pump...
  • Page 2: Table Of Contents

    Operation Functions ....3 (800) 426-5913 www.aseptico.com Operation ......3 Setup Illustrations .
  • Page 3: Introduction

    Your new Aseptico Surgery Irrigation Pump is one of the finest units available to the medical profession. The system features a variable flow control, auto- clavable tubing set, and on/off foot switch operation. These features combine ongratulations to make the perfect irrigation system.
  • Page 4: Setting Up The Unit

    Endo DTC unit or WARNING Surgimotor II unit for simultaneous operation. Never connect or disconnect the bag spike to the irrigation bag over the console. Any liquid spilled and allowed to contact the AEU-7/AEU-7P may cause irreversible damage and will void the warranty.
  • Page 5: Operation Functions

    OPERATION FUNCTIONS: OPERATION: 1. POWER SWITCH - Controls power on/off After the unit has been set up and you have to console. When turned on, green L.E.D made yourself familiar with the operation func- on console should light up. tions, you are ready for operation as follows: 2.
  • Page 6: Setup Illustrations

    AEU-7 with AE-7 On/Off Foot Switch Optional AE-7DC Foot Switch Allows for operation of both the AEU-7 pump and either the Endo DTC or SurgiMotor II electronic rotary systems. AEU-7P connected to AEU-17B or AEU-25 with AE-60 for activation with Pneumatic Foot Control...
  • Page 7: Sterilization & Maintenance

    STERILIZATION & MAINTENANCE: IRRIGATION TUBING SETS - The irrigation tubing sets can be removed from the pump and may be sterilized by autoclave, chemclave, or ethylene oxide gas processes. Follow the man- ufacturer's recommended procedure. The entire tubing set should be sterilized after every patient use.
  • Page 8: Warranty

    Aseptico shall be the sole arbiter of such action. In the event of alleged defect under warranty, the purchaser is to notify Aseptico's Customer Service Department promptly. Customer Service will provide instructions, usually directing that the product be returned for service.