SECTION IV - UNIT OPERATION
A. APPLY ELECTRICAL POWER
Once power is engaged by plugging in your system and/or switching the breaker to the ON
position, your KwiKool System display will come alive and show the current room tempera-
ture. The unit is set to OFF and the fan is set to the default position. A 2.5-minute time delay
starts, indicated by a flashing F or C on the display. If you are not seeing anything on the dis-
play, refer to Section IX, Troubleshooting Guide in this manual.
B. CONTROL PANEL
The touch screen display shows the current operational status of the Unit.
BUTTON
On/Off
On/Off
Up or Down Arrows
Up or Down Arrows
Up or Down Arrows
Mode
Mode
LCD BUTTONS FUNCTIONALITY TABLE
OPERATING IN-
STRUCTIONS
Short Press
Short Press
Short Press
Short Press
Constant Press
Short Press
Short Press
FUNCTION
Start or Stop Operation
EXIT, in Tech and User Set-
tings List
Change Set Point Temperature
Change Parameter Value, in
Tech and User Settings List
Rapid Value Change of Param-
eter or Set Point
Scrolls Through Available Op-
erations
Goes to Next Parameter, in
Tech and User Settings List
12