ADJUSTMENT
POINT
Adjusting
NOTE:
• The POINT adjustments should only be done if necessary. Over
adjusting them may cause the picture distortion.
• The convergence adjustment needs to be performed for each
CRT (R and B) separately.
1) Select "9/POINT" from the "CONVERGENCE"menu and
press ENTER to display the "POINT" menu. For alignment,
select "11/R,G,B POINT" from the "ALIGNMENT" menu and
press ENTER to display the "R,G,B POINT" menu.
2) Use the CURSOR
ENTER to display the selected adjustment screen. You can also
select the item directly by pressing the corresponding INPUT
number button.
• The "CROSS-COARSE" test pattern will be automatically
displayed.
• The POINT convergence screen can be also displayed by
pressing the POINT button on the full function remote
control. The POINT button rotates the adjustment screen in
the following order: COARSE, MEDIUM, FINE.
Items to select
• COARSE ................. Coarse adjustment. Number of adjust-
• MEDIUM
................ Number of adjustment zones is 7 x 7.
• FINE ....................... Fine adjustment. Number of adjustment
3) Use the CURSOR
the point to be adjusted.
• Pressing the CURSOR
Pressing the CURSOR
Pressing the CURSOR
Pressing the CURSOR
bottom.
: adjustment area frame
: adjustment point
4) For alignment, hold down the CTL button, then use the
CURSOR buttons to align the pattern. For convergence, hold
down the CTL button and then use the CURSOR buttons to
align the Red or Blue pattern with the Green pattern.
NOTE: For more accurate convergence correction on edges,
perform the amplitude and linearity adjustments before the
POINT convergence adjustment.
or
button to select the item and press
ment zones is 3 x 3.
points is 13 x 16.
or
buttons to move the cursor mark to
button moves the cursor to the right.
button moves the cursor to the left.
button moves the cursor to the top.
button moves the cursor to the
P O I N T
- C O A R S E -
C R T - R -
When the adjustment area
frame is a box type.
When FINE is selected, the adjustment area frame is not display.
54
– P O I N T –
1 / C O A R S E
2 / M E D I U M
3 / F I N E
When the adjustment area
frame is a box with one side
open.