REGULATOR RESET PROCEDURE

If you are experiencing any of the following performance issues, you may have activated the flow limiting feature in your
regulator:
Burners not getting hot enough.
Low or incomplete burner flames.
Low gas pressure.
Difficulty lighting all burners or burners not staying lit.
Before disconnecting the LP gas cylinder:
1.
With all control knobs in the "OFF" position and the cylinder shut-off valve in the "OFF" position, open the barbecue lid.
2.
Disconnect the regulator from the LP gas cylinder.
3.
Turn all control knobs to the "HI" position, and let stand for 1-3 minutes, allowing all excess gas in the gas manifold to
dissipate.
4.
Turn all control knobs back to the "OFF" position.
5.
With the barbecue lid still OPEN, reconnect the regulator to the LP gas cylinder. Do not cross-thread the connection.
Hand-tighten only.
6.
Check all connections to ensure that a positive seal has been made.
7.
Slowly open the LP gas cylinder shut-off valve.
NOTE
: If the LP gas cylinder is opened too quickly, the flow limiting device in the regulator will activate, limiting the flow
of gas from the LP gas cylinder.
8.
Wait approximately 30 seconds for the regulator pressure to stabilize.
9.
Turn the first control knob to the "HI" position.
10. Press the electronic ignition button, or use a match and the match holder, or a barbecue lighter to ignite the burner.
NOTE
: Avoid activating the flow limiting feature in the regulator by following the proper lighting and shutdown procedures
and performing a complete leak test and safety check to ensure that there are no leaks in the system.