Parameter Setting
Menu
Sub Menu
Beep
Fi off
El
unit
Off
F2 prt
P mode
P baud
parity
P type
U id
U id
Sc id
Sc id
Tech
Beep off
Beep
On in
Beep On out
Lite
aut
Lite
off
Lite
on
Kg / lb
Kilo
lb
0
3
5
15
3 0
Print
Au on
Au off
P cont
Ser re
B 600
B 1200
B 2400
B 4800
B 9600
8 n 1
7 e 1
7 o 1
Tpup
Lp50
abcdef
abcdef
Description
Beeper is turned off
Beeper is turned on, will be
sounded with in the check
weighing limits
Beeper will be sounded above the
check weighing limits
Backlight will be turn on
automatically, when loaded or key
is pressed
Backlight is turned off
Back light is turned on
Weighing Unit kg and lb are enable
Weighing Unit kg only
Weighing Unit lb only
Auto off function disable
Scale will be off three minutes later
Scale will be off five minutes later
Scale will be off 15 minutes later
Scale will be off 30 minutes later
Data out put / accumulation after
unloading the balance
Data out put / accumulation after
by pressing
RS 232 data output continuously
RS 232 data output weight only
Set the required baud
8 bits, no parity
7 bits, even parity
7 bits, no parity
Standard printer setting
Tscale Label Printer
Shows the current User ID (max 6
characters)
Shows the current Scale ID (max 6
characters)
Technical parameter password
protected
- 17 -