Intelligent Weighing Technology GM-3000 Operation Manual

Gm series

Advertisement

Quick Links

GM SERIES
CONTENTS
ELECTRONIC WEIGHING SCALE
1. INTRODUCTION
OPERATION MANUAL
2. INSTALL ATION
PLEASE READ THIS MANUAL VERY CAREFULLY
BEFORE ATTEMPT TO OPERATE THE SCALE
3. EXPLANATIONS
4. OPERATIONS
5. CALIBRATION
6. CARE AND MAINTENANCE
AUGUST 1999 REV 2
7. WARRANTY
Specifications subject to change without prior
notice

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GM-3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Intelligent Weighing Technology GM-3000

  • Page 1 GM SERIES CONTENTS ELECTRONIC WEIGHING SCALE 1. INTRODUCTION OPERATION MANUAL 2. INSTALL ATION PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 3. EXPLANATIONS 4. OPERATIONS 5. CALIBRATION 6. CARE AND MAINTENANCE AUGUST 1999 REV 2 7. WARRANTY Specifications subject to change without prior notice...
  • Page 2: Introduction

    1.1 Models & Specifications: Model Capacity Increment Accuracy GM-3000 3000g GM-6000 6000g 1/3000 GM-15K 15kg 0.005kg GM-30K 30kg 0.01kg...
  • Page 3: Installation

    2. INSTALLATION f. Temperature 0 C – 40 2.1 Unpacking: g. Humidity < 95% RH (Do not install near a humidifier) Unpacking the scale carefully, within this h. Away from other electronic equipment to package you will find: avoid interference. If a leveling bubble a.
  • Page 4: Mode Key

    3. EXPLANATION warranty may be invalidated. Safe use of Power Sources: 3.1 Keypads & Displays: Check that the voltage requirement for the AC adaptor are provided, but not exceeded, by the local power supply. Insert the adaptor plugs securely into a power socket first, then the receptacle on the right-bottom side of the scale.
  • Page 5: Zero Indicator

    7. ZERO INDICATOR backlight (optional). An arrow will appear and point at this sign 5. LO-BAT INDICATOR to indicate a zero weight status. When this indicator appears: a. For battery version: replace IN-CHARGE INDICATOR (BUILT -IN RECHARGEABLE BATTERY VERSION) batteries with new ones, or apply the power adaptor immediately.
  • Page 6 4. OPERATIONS Ground the instrument properly to protect the 4.1 Routine operation: instrumentation from power surges. This can be done by using a suitable adaptor transformer a. Switch power on. The unit will begin a with a third ground terminal. Any method of self-testing sequence.
  • Page 7 Exposure to liquids two modes. f. Press “ ON/ZERO” to reset the scale for Only clean the scale in a manner prescribed normal operation. by the instructions below. Should water or another liquid seep into the Handling the scale enclosure, unplug the unit and have it checked Despite the sturdy appearance of the scale, by your qualified personnel before operating each unit houses sensitive instrumentation...
  • Page 8: Care And Maintenance

    5. CARE AND MAINTENANCE a. Do not subject the commodity platter to sudden shocks. b. Clean the cover and commodity platter with a soft damp cloth and mild detergent. Do not sue harsh abrasives. c. Do not submerge the scale in water and do not pour splash or spray water directly on d.

This manual is also suitable for:

Gm-6000Gm-30kGm-15kGm-1100Gm-11k

Table of Contents