Page 1
Technical Users’ Manual Installation and Operating Instructions MODEL 1036-2 WALL MOUNTED SERVICE STATION CAUTION CAUTION • Inspect unit and all components DO NOT USE CLEANERS • for any loosening that may have CONTAINING CHLORINE WHEN occurred during shipping • CLEANING STAINLESS STEEL •...
Page 2
• Is unit draining properly? WARNING • Are all nuts, bolts, and pins secured in place? It is crucial that any work performed on Mortech Mfg. Inc. If unit has an issue contact customer relations. manufactured items are carried out exclusively by skilled INSTRUCTION FOR HANDLING professionals who have the respective training.
Page 3
MOUNTING INSTRUCTIONS Step 1. Verify all utility rough-ins have been supplied in the proper location and per the project specifications. Drawings from Mortech for utilities are provided with the submittal packet information. Utilities can include: water lines, electrical, drain etc.
Page 4
DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT WRITTEN • Electric Waste Disposal Unit Eyewash Assemblies MODEL 1036-2SS AUTHORIZATION FROM MORTECH MFG. TITLE • Hot and Cold Water Tempering unit with The Wall Mounted Service Station is fabricated of stainless...
Page 5
(626) 334-1704 AND HEREWITH IS NOT TO BE REPRODUCED, USED, OR OTHERWISE www.mortechmfg.com DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT WRITTEN PROJECT MODEL 1036-2SESS AUTHORIZATION FROM MORTECH MFG. TITLE WALL-MOUNTED SERVICE STATION DO NOT SCALE DRAWING APPROVALS DATE...
Page 6
Electrical 1036-2 Wall Mounted Service Station General contractor is recommended to provide: INCOMING MAIN a. Waterproof load center with 1 circuit breaker ELECTRICAL POWER disconnect with a 20 amps fuse (Circuit One) POWER DISCONNECT and 15 amps fuse (Circuit Two) and a point of (CONDUIT) contact for the unit to be installed.
Page 7
A complete collection of our product drawings is available for download at the InSinkErator Revit/CAD Library, which can be found at www.insinkerator.com/foodservice. Product information is also accessible on The KCL CADalog. More information is available from KCL at www.kclcad.com. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 8
120/277 Volt HP Rating: 1HP-120V 2HP-240V-277V Max Amp: 16 Amp Termination: Side Actuator Material: Thermoplastic Body Material: Thermoplastic Strap Material: Steel Standards and Certifications: UL/CSA 110V 220V Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 9
RESET LINE LINE LINE LINE: cable brings power to the GFCI Service Panel Mortech™ Manufacturing Inc. Grounding connection to box ( if box has a 411 North Aerojet Avenue, Azusa, CA 91702 grounding terminal) LOAD LOAD (626) 334-1471 www.mortechmfg.com Wire...
Page 10
Markings The outer surface of the conduit shall be clearly marked with a legible print legend in accordance with UL 1660 and CSA C22.2 No. 227.2. Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 11
2. INSTALL VALVE so that arrows on bracket point upward. If you are making a shower installation only, plug bottom outlet of valve with pipe plug or copper plug. Delta Mixing Valve Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 12
Components Data MAINTENANCE Helpful Hints: 1. Before removing valve cartridge assembly for any maintenance, be sure to note the position of the stop on the cap. The valve cartridge assembly must always be put back in the same position. For normal installations, the stop on the cap will face the left.
Page 13
Components Data This warranty is extensive in that it covers replacement of all defective parts and even finish, but these are the only two things that are covered. LABOR CHARGES AND/OR DAMAGE INCURRED IN INSTALLATION, REPAIR, OR RE- PLACEMENT AS WELL AS ANY OTHER KIND OF LOSS OR DAMAGES ARE EXCLUDED.
Page 14
12” SWING SPOUT Model #3963 12” SWING SPOUT SINGLE WALL CONTROL VALVE w/ SWIVEL OUTLET Model #3700 SINGLE WALL CONTROL VALVE w/ SWIVEL OUTLET 5-3/4” 2” 12” Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 15
7 - HYDRO BOTTOM 8 - HANDLE + 8-32 SET SCREW 9 - LOCKING RING 10 - GLAND NUT 11 - GRAPHITE PACKING 12 - 0-RING 13 - VALVE Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 16
SPRAY HOSE ASSEMBLY SINGLE WALL CONTROL VALVE Model #2700 SPRAY HEAD Model #10820 SPRAY HANDLE Model #2913 SPRAY HOSE Mortech Model #SH10 SPRAY HOSE Mortech Model #SH10 SPRAY HANDLE Model #2913 Feature: Recommended Settings • Single wall • 110ºF at 80 psi •...
Page 17
1036-2 Wall Mounted Service Station Maintenance MAINTENANCE INSTRUCTIONS EFFECTIVE CLEANING METHODS The unit requires regular maintenance and follow the Commercial Cleaners - Many commercial cleaners manufactures directions. compounded from phosphates, synthetic detergents, and DISINFECTING AND CLEANING alkalis are available for the cleaning of severely soiled or Clean all surfaces of the stainless steel with a hard surface stained stainless surfaces.
Page 18
Maintenance record 1036-2 Wall Mounted Service Station MAINTENANCE RECORD Date...
Page 19
1036-2 Wall Mounted Service Station Training record TRAINING RECORD Date...
Page 20
Information in this Manual is subject to change without notice Manufacturing. Inc. will receive the manufacturer’s warranty. and does not represent a commitment on the part of Mortech Manufacturing. Inc. Mortech Manufacturing. Inc. assumes no responsibility for any inaccuracies that may be contained PARTS AND SERVICE in this Manual.
Need help?
Do you have a question about the 1036-2 and is the answer not in the manual?