Page 1
™ Technical Users’ Manual Installation and Operating Instructions MODEL 1036-9 STAINLESS STEEL EMBALMING STATION CAUTION • Inspect unit and all components for any loosening that may have occurred during shipping • ATTENTION Review entire manual before starting assembly JUNE 2010 Mortech™...
• Is unit draining properly? WARNING • Are all nuts, bolts, and pins secured in place? It is crucial that any work performed on Mortech Mfg. Inc. If unit has an issue contact customer relations. manufactured items are carried out exclusively by skilled INSTRUCTION FOR HANDLING professionals who have the respective training.
"Z" Mounting Bracket unit position and insert the flange of the station into the “z” from Mortech for utilities is provided with the submittal packet bar mounting bracket. Lower into position. The unit will fully information. Utilities can include: water lines, electrical, etc.
Page 4
Installation 1036-9 Stainless Steel Embalming Station Figure-G RED TAPE (HOT WATER) BLUE TAPE (COLD WATER) CONNECT TO CONNECT TO Plumbing outlet marked and ready for hook-up. Located inside unit. Figure-G1 COLD, 3/4” HOT, 1/2” PLUMBING CONNECTION INSTRUCTIONS STEP 1: (Refer to Figure-G) Flush out all water lines DRAIN, 1-1/2”...
1036-9 Stainless Steel Embalming Station Installation Cold Water Hot Water Electrical Conduit Whip Connect to building drain GROUND LINE 2 LINE 1 ELECTRICAL CONNECTION INSTRUCTIONS Step 1: (Refer to Figure-I) Connect electrical lines from station to building. Units are provided with watertight conduit lines for connection.
Page 6
Electrical 1036-9 Stainless Steel Embalming Station INCOMING ELECTRICAL POWER 1036-9 ELECTRICAL CONNECTION (CONDUIT) INCOMING ELECTRICAL MAIN POWER POWER (CONDUIT) DISCONNECT BLACK WHITE-NEUTRAL MAIN GREEN-GROUND POWER GFCI DISCONNECT RECEPTACLE BLACK WHITE-NEUTRAL WHITE-NEUTRAL GREEN-GROUND GFCI RECEPTACLE WHITE-NEUTRAL INCOMING ELECTRICAL POWER MAIN POWER...
- Check for proper water flow through the unit 4 gallons per minute - If above two are adequate, disassemble unit and check for debris causing a clog in the unit. - Call mortech customer service if problem persists JUNE 2010 MFGISO DOC. #OM1036-9 (REV C)
™ Component Data DOUBLE PANTRY MIXING FAUCET w/18 INCH COMPLIANT SWING NOZZLE T&S MODEL #B-0270 T&S MODEL #B-0270 Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 9
B - 1.500-28 THREAD Control Valve C - 1/8-27 NPS PIPE THREAD D - 3/4-32 THREAD Model #CP45 OVERALL ASSEMBLY LENGTH = 5.750 INCHES Backflow Preventer Diverter Handle Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
Page 10
Hydro Aspirator Vacuum Breaker INSTALLATION Thread Vacuum Breaker onto Aspirator, tighten. Vacuum Breaker is secured by tightening the set screw. Size: 3⁄4” (20mm) thread Vacuum Breaker is a line of unique vacuum breakers specially TO DRAIN made to permit the attachment of portable hoses to hose Capacity Vacuum Breaker can be drained to prevent freezing by thread faucets.
Page 11
Component Data SPRAY HOSE ASSEMBLY SINGLE WALL CONTROL VALVE Model #2700 SPRAY HEAD Model #10820 SPRAY HANDLE Model #2913 SPRAY HOSE Mortech Model #SH10 WATTS BACKFLOW PREVENTER BACKFLOW PREVENTER N-9 FISHER SINGLE WALL CONTROL VALVE MODEL # 2700 SPRAY HOSE Feature: Mortech Model #SH10 •...
Fisher Spray Hose Assembly Watts Model N9 The remedy described in the first paragraph of this warranty shall constitute the sole and exclusive remedy for breach Backflow Preventers of warranty, and the Company shall not be responsible for any incidental, special or consequential damages, including ATTENTION INSTALLER without limitation, lost profits or the cost of repairing or Before installing, flush out pipe lines to remove scale and...
1036-9 Stainless Steel Embalming Station Maintenance MAINTENANCE INSTRUCTIONS Shop Oil and Grease - These soils may be corrosive and may not allow the surface to maintain passivity, and so MAINTENANCE SCHEDULE removal is a necessity. Soap or detergent and water may be The unit requires regular maintenance and follow the used or a combination of detergent and water plus a solvent.
Need help?
Do you have a question about the 1036-9 and is the answer not in the manual?
Questions and answers