MORTECH 1036-48 Technical  User's Manual

MORTECH 1036-48 Technical User's Manual

Elevating and rotating pedestal autopsy table

Advertisement

Quick Links

MODEL 1036-48
ELEVATING AND ROTATING
PEDESTAL AUTOPSY TABLE
CAUTION
• Inspect unit and all components
for any loosening that may have
occurred during shipping •
ATTENTION
Review entire manual before
starting assembly
ATTENTION
All images and Drawing in this manual
may not represent your model.
Refer to your particular project for
exact specifications
Mortech™ Manufacturing Inc.
411 North Aerojet Avenue, Azusa, CA 91702
(626) 334-1471 www.mortechmfg.com
Technical Users' Manual
Installation and Operating Instructions
CAUTION
DO NOT USE CLEANERS
CONTAINING CHLORINE WHEN
CLEANING STAINLESS STEEL
WARNING
Biohazard Label is place on the
equipment signifying the potentially
infectiousness due to the samples
or reagents
ISO Doc. #OM1036-48 (REV C)
JULY 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1036-48 and is the answer not in the manual?

Questions and answers

Summary of Contents for MORTECH 1036-48

  • Page 1 Technical Users’ Manual Installation and Operating Instructions MODEL 1036-48 ELEVATING AND ROTATING PEDESTAL AUTOPSY TABLE CAUTION CAUTION • Inspect unit and all components DO NOT USE CLEANERS • for any loosening that may have CONTAINING CHLORINE WHEN occurred during shipping •...
  • Page 2: Safety Information

    • Is unit draining properly? WARNING • Are all nuts, bolts, and pins secured in place? It is crucial that any work performed on Mortech If unit has an issue contact Mortech Manufacturing Inc. Manufacturing Inc. manufactured items are carried out...
  • Page 3: Installation

    Attention 1. CUT THE BANDS Please read and follow all the steps below Model Number 1036-48-220 Elevating & Rotating Autopsy Table TABLE TOP 1. This base unit is bolted to the pallet inside of the skirts. 2. Please remove the upper and lower skirts.
  • Page 4: Installation Instructions

    Step 1. Verify all utility rough- ins and project specifications PREPARING THE BUILDING FLOOR that have been supplied for your location. Drawings from Mortech for utilities are provided with the submittal packet WHERE UNIT IS TO BE PLACED Levelness of the unit floor is very important. Please make information.
  • Page 5 1036-48 Elevating and Rotating Pedestal Installation Autopsy Table 1036-48 PANEL ASSEMBLY WARNING WHEN WHEN FLUID APPEARS EXITING THE OVERFLOW DRAIN BLOCKAGE SHOULD BE CLEARED INSIDE UNIT OVERFLOW DRAIN OVERFLOW DRAIN JULY 2013 MFGISO #OM1036-48 (Rev C)
  • Page 6: Electrical Connection Instructions

    Plumbing 1036-48 Elevating and Rotating Pedestal Autopsy Table PLUMBING CONNECTION INSTRUCTIONS ELECTRICAL CONNECTION INSTRUCTIONS Step 1: (Refer to Figure-I) Connect electrical lines from STEP 1: (Refer to Figure-G) Flush out all water lines prior station to building. Units are provided with watertight to connection.
  • Page 7 1036-48 Elevating and Rotating Pedestal Electrical Autopsy Table PLUMBING CONNECTION CONT... SWIVEL BEARING RING DRAIN HYDRAULIC LIFT SYSTEM HYDRAULIC LIFT SYSTEM ELECTRICAL CONDUIT MOUNTING ANGLE COLD WATER HOT WATER WARNING WHEN WHEN FLUID APPEARS EXITING THE OVERFLOW DRAIN BLOCKAGE SHOULD BE CLEARED INSIDE UNIT...
  • Page 8: Parts Listing

    - If above two are adequate, disassemble unit and check for - Contact plumber to diagnose and clear debris causing a clog in the unit. drain if problem persist - Call Mortech customer service if problem persists Rust developing - Check for standing water in rust area remove standing water...
  • Page 9: Optional Accessories

    1036-48 Elevating and Rotating Pedestal Parts listing Autopsy Table HYDRO ASPIRATOR HOT/COLD MIXING FAUCET TURN CONTROL VALVE ON/OFF w/WRIST BLADE HANDLES TURN LEVER ON UNIT TO GOOSENECK SWING NOZZLE REVERSE FLOW (USE LEVERS TO TEMPER WATER) VACUUM BREAKER 180º ROTATION...
  • Page 10 1036-48 Elevating and Rotating Pedestal Accessories Autopsy Table ELEVATING MECHANISM Step 1. Push the Elevating Switch upward to elevate the table. Do not excess maximum height or force the table upward. Step 2. Push the Elevating Switch downward to lower the table.
  • Page 11 1036-48 Elevating and Rotating Pedestal Accessories Autopsy Table Digital Scale Emergency Eyewash The Ohaus Compact Scale Hose Assembly is ideal when cost matters Hand control spray to provide a gentle and dependable results are of water to rinse eyes of foreign debris.
  • Page 12: Component Data

    • CSA Certified (File #LR-57811 nuisance tripping • NOM Certified (File #057) • Impact-resistant thermoplastic cover and body Material Characteristics Environmental: Flammability UL-94 V2 Rating Operating Temperature: -35°C to 65°C Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
  • Page 13 • Patented Quick-Fit™ Key Hole Mount for Easy Installation • Patented Universal-Fit™ Adapter Technology • Lockable Tab • Premium Powdercoat Finish • Spring Hinge Closure • UL Listed & 2008 NEC Compliant Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
  • Page 14 HOT/COLD MIXING FAUCET Model #133X T&S DECK MOUNT FAUCET w/GOOSENECK NOZZLE Model #B-0225-LN T&S Model #B-0413 T&S Model #B-0413 T&S DECK MOUNT FAUCET w/WRIST BLADES Model #B-0225-LN Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
  • Page 15 8 - HANDLE + 8-32 SET SCREW 9 - LOCKING RING 10 - GLAND NUT 11 - GRAPHITE PACKING Diverter 12 - 0-RING Handle Control Valve 13 - VALVE Model #CP45 Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
  • Page 16 *Performance as established by an independent testing laboratory. Dimensions – Weights MODE SIZE (DN DIMENSION WEIGHT 3 ⁄4HT 1 1 ⁄2 1 3 ⁄8 113.4 Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 Dimensions – Weights (626) 334-1471 www.mortechmfg.com...
  • Page 17: Warranty

    PART NO. DESCRIPTION 420-010 SCREW 633-223 INDEX BUTTON (WHITE) MODEL 45-CP 633PL 4-ARM PLAIN HANDLE ASSEMBLY 1-214 217XTLH SLO-COMPRESSION UNIT (LH) ------- VALVE BODY (NOT SOLD SEPARATELY) Mortech™ Manufacturing Inc. 411 North Aerojet Avenue, Azusa, CA 91702 (626) 334-1471 www.mortechmfg.com...
  • Page 18 SPRAY HOSE ASSEMBLY SINGLE WALL CONTROL VALVE Model #2700 SPRAY HEAD Model #10820 SPRAY HANDLE Model #2913 SPRAY HOSE Mortech Model #SH10 SPRAY HOSE Mortech Model #SH10 FISHER SINGLE WALL CONTROL VALVE MODEL # 2700 Feature: • Single wall • Stem - right hand •...
  • Page 19: Maintenance Instructions

    1036-48 Elevating and Rotating Pedestal Maintenance Autopsy Table MAINTENANCE INSTRUCTIONS The unit requires regular maintenance and follow the EFFECTIVE CLEANING METHODS manufactures directions. Commercial Cleaners - Many commercial cleaners DISINFECTING AND CLEANING compounded from phosphates, synthetic detergents, and Clean all surfaces of the stainless steel with a hard surface alkalis are available for the cleaning of severely soiled or disinfectant/cleaner such as Sheila Shine®...
  • Page 20: Maintenance Record

    1036-48 Elevating and Rotating Pedestal Maintenance record Autopsy Table MAINTENANCE RECORD Date JULY 2013 MFGISO #OM1036-48 (Rev C)
  • Page 21: Training Record

    Training record 1036-48 Elevating and Rotating Pedestal Autopsy Table TRAINING RECORD Date JULY 2013 MFGISO #OM1036-48 (Rev C)
  • Page 22 Information in this Manual is subject to change without notice of (18) months from the date of shipment. Shipping and and does not represent a commitment on the part of Mortech Labor is not warranted. Items not manufactured by Mortech Manufacturing.

Table of Contents