Table 10 Ip Setup - ZyXEL Communications ES-315 - V3.70 User Manual

Intelligent layer 2 managed switch
Table of Contents

Advertisement

Chapter 6 Basic Setting
The following table describes the labels in this screen.

Table 10 IP Setup

LABEL
Domain Name
Server
Default Management IP Address
DHCP Client
Static IP Address
IP Address
IP Subnet Mask
Default Gateway
VID
Apply
Cancel
Management IP Addresses
You can create up to 4 IP addresses, which are used to access and manage the switch from the ports
belonging to the pre-defined VLAN(s). You must configure a VLAN first.
IP Address
IP Subnet Mask
VID
Default Gateway
Add
Cancel
Index
IP Address
IP Subnet Mask
VID
Default Gateway
52
DESCRIPTION
DNS (Domain Name System) is for mapping a domain name to its
corresponding IP address and vice versa. Enter a domain name server IP
address in order to be able to use a domain name instead of an IP address.
Select this option if you have a DHCP server that can assign the switch an IP
address, subnet mask, a default gateway IP address and a domain name server
IP address automatically.
Select this option if you don't have a DHCP server or if you wish to assign static
IP address information to the switch. You need to fill in the following fields when
you select this option.
Enter the IP address of your switch in dotted decimal notation for example
192.168.1.1.
Enter the IP subnet mask of your switch in dotted decimal notation for example
255.255.255.0.
Enter the IP address of the default outgoing gateway in dotted decimal notation,
for example 192.168.1.254.
Enter the VLAN identification number associated with the switch IP address.
This is the VLAN ID of the CPU and is used for management only. The default is
"1". All ports, by default, are fixed members of this "management VLAN" in order
to manage the device from any port. If a port is not a member of this VLAN, then
users on that port cannot access the device. To access the switch make sure
the port that you are connected to is a member of Management VLAN.
Click Apply to save your changes to the switch's run-time memory. The switch
loses these changes if it is turned off or loses power, so use the Save link on the
top navigation panel to save your changes to the non-volatile memory when you
are done configuring.
Click Cancel to begin configuring the fields again.
Enter the IP address for managing the switch by the members of the VLAN
specified in the VID field below.
Enter the IP subnet mask in dotted decimal notation.
Type the VLAN group identification number.
Enter the IP address of the default outgoing gateway in dotted decimal notation.
Click Add to insert the entry to the summary table below and save your changes
to the switch's run-time memory. The switch loses these changes if it is turned
off or loses power, so use the Save link on the top navigation panel to save your
changes to the non-volatile memory when you are done configuring.
Click Cancel to reset the fields to your previous configuration.
This field displays the index number of the rule. Click an index number to edit
the rule.
This field displays the IP address.
This field displays the subnet mask.
This field displays the ID number of the VLAN group.
This field displays the IP address of the default gateway.
ES-315/ES-315-F User's Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-315Es-315-f