Accessing Fryers For Service - Dean BK1814 Service & Parts Manual

High efficiency decathlon (hd) series gas fryers
Table of Contents

Advertisement

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
Thermostats
Different types of thermostats are used in High Efficiency Decathlon Series gas fryers, depending on
fryer configuration.
Fryers equipped with a Thermatron use a dial to adjust temperature. In this configuration, the probe
resistance varies inversely with the temperature. As the temperature rises, resistance decreases at a
non-linear rate. A chart is located at the end of this chapter.
Fryers equipped with controller controls have a temperature probe. In this configuration, the probe
resistance varies directly with the temperature. As the temperature rises, resistance increases at a
rate of approximately 2 ohms for every 1°F (approximately 3.7 ohms for every 1°C). Circuitry in the
controller monitors the probe resistance and controls burner firing when the resistance exceeds or
falls below programmed temperatures (setpoints). The temperatures are programmed by means of a
keypad on the face of the controller.
All HD Series gas fryers are equipped with a high-limit thermostat. In the event that the fryer fails
to control the oil temperature, the high-limit thermostat prevents the fryer from overheating to flash
point. The high-limit thermostat acts as a normally closed power switch that opens when exposed to
temperatures above 450°F/232°C.

1.2 Accessing Fryers for Service

Moving a fryer filled with cooking oil may cause spilling or splattering of the hot
liquid. Follow the draining instructions included with the fryer before attempting to
1. Shut off the gas supply to the unit. Unplug the power cords. Remove any attached restraining
devices.
2. Disconnect the unit from the gas supply.
3. Relocate the fryer for service accessibility.
4. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and
plug in the electrical cords.
No structural material on the fryer should be altered or removed to accommodate
placement of the fryer under a hood. Questions? Call the Frymaster Dean Service
CHAPTER 1: SERVICE PROCEDURES
DANGER
relocate a fryer for servicing.
DANGER
Hotline at 1-800-551-8633.
1-7

Advertisement