Dean BK1814 Service & Parts Manual page 22

High efficiency decathlon (hd) series gas fryers
Table of Contents

Advertisement

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
1.7.3 Replacing the High-limit Thermostat
8. Mark and disconnect wires at the high-limit in the
component box.
9. Remove high-limit from fryer by pulling the
capillary tube and bulb through the component box
opening (arrow). This may require removal of the
control panel frame.
10. Reverse the above steps for high-limit installation.
IMPORTANT: When installing new high-limit,
ensure the capillary tube and bulb are positioned
properly with tab back in alignment prior to tightening
the compression nut. Once tightened, the capillary
tube cannot be repositioned.
CHAPTER 1: SERVICE PROCEDURES
(cont.)
1-17
Mark
and
disconnect
(arrows).
Reconnect wires to the same
terminals on the replacement high-limit.
Component box opening (arrow).
high-limit
wiring

Advertisement