Siegenia AERO AEROVITAL ambience Original Operating Instructions

Siegenia AERO AEROVITAL ambience Original Operating Instructions

Advertisement

Quick Links

ORIGINAL OPERATING
INSTRUCTIONS
AERO
AEROVITAL ambience
Wall-mounted ventilator with sound absorption.
Window systems
Door systems
Comfort systems

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AERO AEROVITAL ambience and is the answer not in the manual?

Questions and answers

Summary of Contents for Siegenia AERO AEROVITAL ambience

  • Page 1 ORIGINAL OPERATING INSTRUCTIONS AERO AEROVITAL ambience Wall-mounted ventilator with sound absorption. Window systems Door systems Comfort systems...
  • Page 2: Table Of Contents

    SAFETY NOTES ...........4 ACCESSORIES ..........14 GENERAL NOTES ........4 RECTIFICATION OF MALFUNCTIONS ..15 SCOPE OF DELIVERY AND EQUIPMENT ..5 13.1 SIEGENIA Comfort app ........ 16 UNIT DESCRIPTION ........6 TECHNICAL SPECIFICATIONS ....17 Unit function ..........6 DIMENSIONS ...........17 Designation of parts ........7 PRODUCT DATA SHEET LED INDICATOR ..........8...
  • Page 3: Target Group Of This Documentation

    "Maintenance" chapter. Do buildings). not remove the cover of the connecting clamps • Be sure to mount the supplied SIEGENIA weather inside the unit. grille for the protection of the unit from the outer • Please make sure that the unit is not switched off side.
  • Page 4: Safety Notes

    – If any work is required for the connection of the days in succession. device to the 230 V AC mains power supply, this • Danger due to third party attacks on SIEGENIA may only be carried out by an electrician. WIFI devices! Please observe the following notes to –...
  • Page 5: Scope Of Delivery And Equipment

    AEROVITAL ambience Original operating instructions Quick start instructions ― Heat recovery: Keyboard lock (child-proof lock) Temperature and humidity sensor Air quality sensor with CO and TVOC ― regulation Operation via SIEGENIA Comfort app ― Assembly set Unit set H47.WANS007EN-03 09.2023 5/20...
  • Page 6: Unit Description

    Original operating instructions AERO AEROVITAL ambience Unit description 6.1 Unit function 6.1.2 Ventilation in automatic mode 6.1.1 Ventilation and aeration with blower and heat • The blower levels 1 to 5 are controlled in automatic recovery mode. The necessary blower level is dependent on the temperature and air humidity as well as optionally on the CO value and on the TWOC value.
  • Page 7: Designation Of Parts

    Original operating instructions AERO AEROVITAL ambience 6.2 Designation of parts 1. On/Off (and brightness sensor 2. Blower levels 1 to 5 3. Automatic mode (AUTO) 4. Heat recovery (WRG) 5. Supply air ventilation slots 6. Exhaust air ventilation slots 7. Mains cable with Euro plug (alternative fixed connection) 1) Depending on the light intensity in the room, the brightness sensor automatically regulates the brightness of the LED indicator.
  • Page 8: Led Indicator

    Original operating instructions AERO AEROVITAL ambience LED indicator 7.1 Operating status Operating status Warm-up phase during the calibration »AUTO« flashes (see calibration, page 9) »Blower level« Selected blower level is active lights up »AUTO« lights up Automatic mode is active* »WRG«...
  • Page 9: Commissioning

    • The automatic mode already functions during the warm-up phase. • The calibration starts automatically. • The air quality is already displayed during the calibration in the SIEGENIA Comfort app. • The accuracy of the sensor rises with the continuing duration of the calibration. Operation 9.1 Buttons on the unit...
  • Page 10: Operation Via Smartphone Or Tablet (Aerovital Ambience Smart Only)

    The AEROVITAL ambience smart can be controlled by 10.2.3 Automatic mode a tablet or smartphone and offers additional device functions via the SIEGENIA Comfort app. For information on the automatic mode, see page 6. 10.2.4 Silent mode The silent mode restricts the blower performance, thus overriding all blower levels that are programmed in other functions (e.
  • Page 11: Maintenance

    The safety devices must be removed if necessary. 11.1 Cleaning • Only use the original filters from SIEGENIA. You can purchase replacement filters from SIEGENIA or from • Important: when cleaning the AEROVITAL ambience, specialist retailers (see accessories page 14).
  • Page 12 Original operating instructions AERO AEROVITAL ambience Release and remove the top cover plate Insert the new air supply filter Remove the muffler Position the muffler in the centre Remove the polluted supply air filter Position the top cover plate Remove and clean the soiled insect screen Fix the top cover plate WARNING Strong gravitational pull of the magnets...
  • Page 13 Original operating instructions AERO AEROVITAL ambience Release and remove the bottom cover plate Position the exhaust air filter and filter bracket in the centre Remove the exhaust air filter and filter bracket (left and Position and fix the bottom cover plate right) WARNING Strong gravitational pull of the magnets...
  • Page 14: Accessories

    AEROVITAL ambience Close the casing cover The filter change display must be reset after changing the filter. This is done either using the SIEGENIA Comfort app ① or by pressing the Minus and Plus buttons alternately ② Accessories Material description...
  • Page 15: Rectification Of Malfunctions

    In case of a malfunction, do not open the unit or try to repair it under any circumstances. If the problem is not listed in the table below, please contact your installation firm or SIEGENIA directly: tel. +49 271 3931-0...
  • Page 16: Siegenia Comfort App

    • Automatic mode limited • Condensate and frost protection control limited 13.1 SIEGENIA Comfort app You will find detailed information on operation and on how to rectify malfunctions using the SIEGENIA Comfort app on the SIEGENIA Smarthome Internet page. https://smarthome.siegenia.com 16/20 09.2023 H47.WANS007EN-03...
  • Page 17: Technical Specifications

    Original operating instructions AERO AEROVITAL ambience 14 Technical specifications AEROVITAL ambience AEROVITAL ambience smart Level 1 L = 20 dB (A) Level 1 L = 20 dB (A) Level 2 L = 22 dB (A) Level 2 L = 22 dB (A) Inherent noise Level 3 L = 25 dB (A) Level 3 L...
  • Page 18: Product Data Sheet

    Original operating instructions AERO AEROVITAL ambience 16 Product data sheet (in accordance with EU Regulation 1254/2014) Producer SIEGENIA SIEGENIA Model identifier AEROVITAL ambience AEROVITAL ambience smart Energy consumption (SEC); ‒ 16.82 kWh/(m² . a); E ‒ 17.72 kWh/(m² . a); E Energy efficiency class (SEC class) ―...
  • Page 19: Eu Declaration Of Conformity With Regard To Ce Marking

    EN 50581:2012 Technical documentation on the evaluation of electrical and electronic devices with reference to the restriction of hazardous substances This declaration is responsible for the producers / importers based in the European Union submitted by: SIEGENIA-AUBI KG Hardware and ventilation technology Siegen, 2017-03-30 Duisburger Straße 8...
  • Page 20 www.siegenia.com...

Table of Contents